Library Reference

This is a dictionary of all referenced libraries and their name spaces.

3SLicense

Library Identification

Placeholder: 3SLicense
Default Resolution: 3SLicense, * (CODESYS)
Namespace: _3S_LICENSE

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: 3SLicense

Base Interfaces

Library Identification

Name: Base Interfaces
Version: newest
Company: System
Namespace: IBaseLibrary

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Base Interfaces, * (System)

CAA Callback Extern

Library Identification

Placeholder: CAA Callback
Default Resolution: CAA Callback Extern, * (CAA Technical Workgroup)
Namespace: CB

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Callback

CAA Device Diagnosis

Library Identification

Placeholder: CAA Device Diagnosis
Default Resolution: CAA Device Diagnosis, * (CAA Technical Workgroup)
Namespace: DED

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Device Diagnosis

CAA Types Extern

Library Identification

Placeholder: CAA Types
Default Resolution: CAA Types Extern, * (CAA Technical Workgroup)
Namespace: CAA

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Types

CmpApp

Library Identification

Placeholder: CmpApp
Default Resolution: CmpApp, * (System)
Namespace: CmpApp

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpApp

CmpErrors2 Interfaces

Library Identification

Name: CmpErrors2 Interfaces
Version: newest
Company: System
Namespace: CmpErrors

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpErrors2 Interfaces, * (System)

CmpEventMgr

Library Identification

Placeholder: CmpEventMgr
Default Resolution: CmpEventMgr, * (System)
Namespace: CmpEventMgr

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpEventMgr

CmpIecTask

Library Identification

Placeholder: CmpIecTask
Default Resolution: CmpIecTask, * (System)
Namespace: CmpIecTask

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpIecTask

CmpLog

Library Identification

Placeholder: CmpLog
Default Resolution: CmpLog, * (System)
Namespace: CmpLog

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpLog

Component Manager

Library Identification

Placeholder: Component Manager
Default Resolution: Component Manager, * (System)
Namespace: Component_Manager

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Component Manager

Empty

Library Identification

Placeholder: SoftMotion_BusTaskInterval
Default Resolution: Empty, * (3S - Smart Software Solutions GmbH)
Namespace: SoftMotion_BusTaskInterval

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SoftMotion_BusTaskInterval

FloatingPointUtils

Library Identification

Placeholder: FloatingPointUtils
Default Resolution: FloatingPointUtils, * (System)
Namespace: FPU

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: FloatingPointUtils

IoDriver Interfaces

Library Identification

Name: IoDriver Interfaces
Version: newest
Company: System
Namespace: IoDriver_Interfaces

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: IoDriver Interfaces, * (System)

IoStandard

Library Identification

Placeholder: IoStandard
Default Resolution: IoStandard, * (System)
Namespace: IoStandard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: IoStandard

SM3_CommonPublic

Library Identification

Placeholder: SM3_CommonPublic
Default Resolution: SM3_CommonPublic, * (CODESYS)
Namespace: SM3_Common

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_CommonPublic

SM3_Error

Library Identification

Placeholder: SM3_Error
Default Resolution: SM3_Error, * (CODESYS)
Namespace: SM3_Error

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_Error

SM3_Math

Library Identification

Placeholder: SM3_Math
Default Resolution: SM3_Math, * (CODESYS)
Namespace: SM3M

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_Math

SM3_RBase

Library Identification

Placeholder: SM3_RBase
Default Resolution: SM3_RBase, * (CODESYS)
Namespace: SMRB

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_RBase

SM3_Ramps

Library Identification

Placeholder: SM3_Ramps
Default Resolution: SM3_Ramps, * (CODESYS)
Namespace: SM3_Ramps

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_Ramps

SM3_Shared

Library Identification

Placeholder: SM3_Shared
Default Resolution: SM3_Shared, * (CODESYS)
Namespace: SM0

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_Shared

SM3_TrajectoryGeneration

Library Identification

Placeholder: SM3_TrajectoryGeneration
Default Resolution: SM3_TrajectoryGeneration, * (CODESYS)
Namespace: SM3_TrajectoryGeneration

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_TrajectoryGeneration

Standard

Library Identification

Placeholder: Standard
Default Resolution: Standard, * (System)
Namespace: Standard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Standard

SysCpuHandling

Library Identification

Placeholder: SysCpuHandling
Default Resolution: SysCpuHandling, * (System)
Namespace: SysCpuHandling

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysCpuHandling

SysFile

Library Identification

Placeholder: SysFile
Default Resolution: SysFile, * (System)
Namespace: SysFile

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysFile

SysMem

Library Identification

Placeholder: SysMem
Default Resolution: SysMem, * (System)
Namespace: SysMem

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysMem

SysTarget

Library Identification

Placeholder: SysTarget
Default Resolution: SysTarget, * (System)
Namespace: SysTarget

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTarget

SysTime

Library Identification

Placeholder: SysTime
Default Resolution: SysTime, * (System)
Namespace: SysTime

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTime

SysTypes2 Interfaces

Library Identification

Name: SysTypes2 Interfaces
Version: newest
Company: System
Namespace: SysTypes

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTypes2 Interfaces, * (System)

VisuElem3DPath

Library Identification

Placeholder: System_VisuElem3DPath
Default Resolution: VisuElem3DPath, 3.5.15.0 (System)
Namespace: VisuElem3DPath

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElem3DPath

Library Parameter

Parameter: GC_POINTS_PER_POLYGON = 100

VisuElemCamDisplayer

Library Identification

Placeholder: System_VisuElemCamDisplayer
Default Resolution: VisuElemCamDisplayer, 3.5.15.0 (System)
Namespace: VisuElemCamDisplayer

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemCamDisplayer

Library Parameter

Parameter: GC_POINTS_PER_CAM = 100

VisuElemMeter

Library Identification

Placeholder: System_VisuElemMeter
Default Resolution: VisuElemMeter, 3.5.15.0 (System)
Namespace: VisuElemMeter

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemMeter

VisuElemTextEditor

Library Identification

Placeholder: System_VisuElemTextEditor
Default Resolution: VisuElemTextEditor, 3.5.15.0 (System)
Namespace: VisuElemTextEditor

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemTextEditor

VisuElemTrace

Library Identification

Placeholder: System_VisuElemTrace
Default Resolution: VisuElemTrace, 3.5.15.0 (System)
Namespace: VisuElemTrace

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemTrace

VisuElemXYChart

Library Identification

Placeholder: System_VisuElemXYChart
Default Resolution: VisuElemXYChart, 3.5.15.0 (System)
Namespace: VisuElemXYChart

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemXYChart

VisuElems

Library Identification

Placeholder: System_VisuElems
Default Resolution: VisuElems, 3.5.15.0 (System)
Namespace: VisuElems

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElems

VisuElemsAlarm

Library Identification

Placeholder: System_VisuElemsAlarm
Default Resolution: VisuElemsAlarm, 3.5.15.0 (System)
Namespace: VisuElemsAlarm

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsAlarm

VisuElemsDateTime

Library Identification

Placeholder: System_VisuElemsDateTime
Default Resolution: VisuElemsDateTime, 3.5.15.0 (System)
Namespace: VisuElemsDateTime

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsDateTime

VisuElemsSpecialControls

Library Identification

Placeholder: System_VisuElemsSpecialControls
Default Resolution: VisuElemsSpecialControls, 3.5.15.0 (System)
Namespace: VisuElemsSpecialControls

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsSpecialControls

VisuElemsWinControls

Library Identification

Placeholder: System_VisuElemsWinControls
Default Resolution: VisuElemsWinControls, 3.5.15.0 (System)
Namespace: VisuElemsWinControls

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsWinControls

VisuInputs

Library Identification

Placeholder: system_visuinputs
Default Resolution: VisuInputs, 3.5.15.0 (System)
Namespace: visuinputs

Library Properties

  • LinkAllContent: False

  • Optional: False

  • PublishSymbolsInContainer: True

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: system_visuinputs

VisuNativeControl

Library Identification

Placeholder: System_VisuNativeControl
Default Resolution: VisuNativeControl, 3.5.15.0 (System)
Namespace: VisuNativeControl

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuNativeControl