MC_Home_SML (FB)¶
FUNCTION_BLOCK FINAL MC_Home_SML
Commands the axis to perform the «search home» sequence. The details of this sequence are manufacturer specific and can be set by the axis’ parameters. The ‘Position’ input is used to set the absolute position when the reference signal is detected.
After completion, the axis state is Standstill if it was Standstill when started.
- InOut:
- Scope - Name - Type - Comment - Inout - Axis- Reference to the axis - Input - Execute- BOOL- Rising edge: The homing is started - Position- LREAL- Absolute position when the reference signal is detected (in technical units [u]) - Output - Done- BOOL- Reference known and set successfully - Busy- BOOL- Homing is not finished and new output values are to be expected - CommandAborted- BOOL- Homing was aborted by a motion command acting on the same axis - Error- BOOL- Signals that an error has occured - ErrorID- Error number 
