IBACnetStaticObjectBase (ITF)ΒΆ
INTERFACE PUBLIC IBACnetStaticObjectBase EXTENDS IBACnetObjectBase
Any BACnet-Object inserted as CODESYS-Device is reflected by an FB derived by this FB-Type. It establishes zhe correct initialization of the BACnet-Properties using the CODESYS-Devices Parameters.
Properties:
DeviceInstNumber, inherited from IBACnetObjectBase
NumberOfProperties, inherited from IBACnetObjectBase
ObjectID, inherited from IBACnetObjectBase
Methods:
GetBACnetAccumulatorRecordProperty, inherited from IBACnetObjectBase
GetBACnetBitStringProperty, inherited from IBACnetObjectBase
GetBACnetBooleanProperty, inherited from IBACnetObjectBase
GetBACnetClientCOVProperty, inherited from IBACnetObjectBase
GetBACnetDateProperty, inherited from IBACnetObjectBase
GetBACnetDateRangeProperty, inherited from IBACnetObjectBase
GetBACnetDateTimeProperty, inherited from IBACnetObjectBase
GetBACnetDevObjPropReferenceProperty, inherited from IBACnetObjectBase
GetBACnetEnumeratedProperty, inherited from IBACnetObjectBase
GetBACnetObjPropReferenceProperty, inherited from IBACnetObjectBase
GetBACnetObjectIDProperty, inherited from IBACnetObjectBase
GetBACnetPrescaleProperty, inherited from IBACnetObjectBase
GetBACnetRealProperty, inherited from IBACnetObjectBase
GetBACnetScaleProperty, inherited from IBACnetObjectBase
GetBACnetSetpointReferenceProperty, inherited from IBACnetObjectBase
GetBACnetSignedProperty, inherited from IBACnetObjectBase
GetBACnetStringProperty, inherited from IBACnetObjectBase
GetBACnetTimeProperty, inherited from IBACnetObjectBase
GetBACnetTimeStampProperty, inherited from IBACnetObjectBase
GetBACnetUnsignedProperty, inherited from IBACnetObjectBase
GetPropertyCallbackAttachment, inherited from IBACnetObjectBase
GetPropertyId, inherited from IBACnetObjectBase
GetPropertyInstance, inherited from IBACnetObjectBase
GetPropertyInstanceStackAllocContentBuffer, inherited from IBACnetObjectBase
GetPropertyInstanceWithContentBuffer, inherited from IBACnetObjectBase
IsPropertyExistent, inherited from IBACnetObjectBase
IsPropertyWriteable, inherited from IBACnetObjectBase
SetBACnetAccumulatorRecordProperty, inherited from IBACnetObjectBase
SetBACnetBitStringProperty, inherited from IBACnetObjectBase
SetBACnetBooleanProperty, inherited from IBACnetObjectBase
SetBACnetClientCOVProperty, inherited from IBACnetObjectBase
SetBACnetDateProperty, inherited from IBACnetObjectBase
SetBACnetDateRangeProperty, inherited from IBACnetObjectBase
SetBACnetDateTimeProperty, inherited from IBACnetObjectBase
SetBACnetDevObjPropReferenceProperty, inherited from IBACnetObjectBase
SetBACnetEnumeratedProperty, inherited from IBACnetObjectBase
SetBACnetObjPropReferenceProperty, inherited from IBACnetObjectBase
SetBACnetObjectIDProperty, inherited from IBACnetObjectBase
SetBACnetPrescaleProperty, inherited from IBACnetObjectBase
SetBACnetRealProperty, inherited from IBACnetObjectBase
SetBACnetScaleProperty, inherited from IBACnetObjectBase
SetBACnetSetpointReferenceProperty, inherited from IBACnetObjectBase
SetBACnetSignedProperty, inherited from IBACnetObjectBase
SetBACnetStringProperty, inherited from IBACnetObjectBase
SetBACnetTimeProperty, inherited from IBACnetObjectBase
SetBACnetTimeStampProperty, inherited from IBACnetObjectBase
SetBACnetUnsignedProperty, inherited from IBACnetObjectBase
SetObjectName, inherited from IBACnetObjectBase
SetPropertyAccessRight, inherited from IBACnetObjectBase
SetPropertyCallbackAttachment, inherited from IBACnetObjectBase
SetPropertyInstance, inherited from IBACnetObjectBase
WritePropertyInstance, inherited from IBACnetObjectBase
Structure: