SMC_ReadNCFromStream (FB)¶
FUNCTION_BLOCK SMC_ReadNCFromStream
SMC_ReadNCFromStream can read an NC-ASCII-file from a stream
in order to make it available for the SMC_NCInterpreter.
Thus, an NC program can be read in and interpreted at runtime.
- InOut:
Scope
Name
Type
Initial
Comment
Input
bExecuteBOOLRising edge: starts execution.
bAppendBOOLIf
TRUE`, no default values are added (like G17 for 3D mode). Intended to be used together with the inputbAppendof SMC_NCInterpreter. Note: must not be TRUE for the first rising edge ofbExecute.bAbortBOOLIf
TRUE, the current processing of this function block is abortedaStreamARRAY [0..SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH] OF SMC_ITextStream
An array of streams. aStream[0] has to contain the main program. It must be open and ready for reading. The streams 1 .. N-1 are (only) used to process subprogram calls. The streams must be of the correct type for the implementation of
lookupCNCProgram.lookupCNCProgramAn object that looks up subprograms by name. Used to open the streams for the subprograms (
aSubStreams).pvlPOINTER TO SMC_VARLIST
A variable list defining type and address for each variable that can be used from the g-code. If there are no variables in the g-code, this input is not used.
fDefaultVelLREALDefault velocity; used if the velocity (F-word) is not specified inside the CNC file. Note: only applies to the main program, not to subprograms.
fDefaultAccelLREALDefault acceleration; used if acceleration (E+ word) is not specified inside the CNC file Note: only applies to the main program, not to subprograms.
fDefaultDecelLREALDefault deceleration (E- word); used if deceleration is not specified inside the CNC file. A non-negative value is expected. Note: only applies to the main program, not to subprograms.
fDefaultVelFFLREALDefault velocity for fast forward (G0), FF word. It is used if no velocity is specified inside the CNC file. Note: only applies to the main program, not to subprograms.
fDefaultAccelFFLREALDefault acceleration for fast forward (G0), EF+ word. It is used if no acceleration is specified inside the CNC file. Note: only applies to the main program, not to subprograms.
fDefaultDecelFFLREALDefault deceleration for fast forward (G0), EF- word. A non-negative value is expected. It is used if no deceleration is specified inside the CNC file. Note: only applies to the main program, not to subprograms.
b3DModeBOOLTRUE
If
TRUE, a G17 command (activation of 3D-mode) is executed implicitly. Note: only applies to the main program, not to subprograms.bStepSuppressBOOLWhen this input is
TRUE, lines of the CNC program starting with ‚/’ will be ignored. Otherwise they will be processed.bParenthesesAsCommentsBOOLTRUE
Usually, parentheses in g-code are treated as multi-line comments. If bParenthesesAsComments is set to FALSE, however, parentheses can be used in the usual ways to group expressions (‘(a+b)*c’) and for subprogram calls (‘N10 sub(17)’) in g-code. Multi-line comments can be started with ‘(’ and end with ‘)’.
For more control over the delimiters, call the method SMC_ReadNCFromStream.SetDelimiters before calling the main method of this FB. If SetDelimiters is called, this input is ignored.
Note
Regardless of the value of this input, it is always possible to use curly braces ‘{}’ to group expressions and for subprogram calls.
bDisableJumpBufferBOOLThis input, if
TRUE, disables an internal jump buffer that is used to improve performance of g-code processing if jumps (G20) are used.pCustomFunTablePOINTER TO SMC_NC_GFunctionTable
Allows to define custom functions that can be used in G-Code expressions. If there are no custom G-Code functions, this input is null.
aTokenModifierARRAY [0..SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH] OF SMC_ITokenModifier
Optional modifier function blocks that can change the tokens on the fly. This can be used to translate between G-Code dialects. Leave 0 if not needed. Otherwise, set all members of the array to valid function block instances.
aSentenceModifierARRAY [0..SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH] OF SMC_IGSentenceModifier
Optional modifier function blocks that can change the g-code sentences on the fly. This can be used to translate between G-Code dialects. Leave 0 if not needed. Otherwise, set all members of the array to valid function block instances.
Output
bBusyBOOLTRUEwhile execution of function block is not finishedbErrorBOOLTRUEsignals that an error has occurred within the function block.ErrorIDSMC_ERRORError identification
errorPosThe source-position where an error has been detected.
ErrorProgramNameSTRINGThe name of the program where an error has been detected
nActiveChainUDINTThe currently active parsing chain, 0 <= nActiveChain < NUM_PARSER_CHAINS.
Inout
sentencesOut: The output sentence queue that can be fed into SMC_NCInterpreter.
Methods:
Structure: