SF_ESPE (FB)ΒΆ
FUNCTION_BLOCK SF_ESPE
- InOut:
Scope
Name
Type
Initial
Comment
Input
ActivateBOOLFALSE
Activation of the FB.
S_ESPE_InBOOLFALSE
Safety demand input. FALSE: ESPE actuated, demand for safety-related response. TRUE: ESPE not actuated, no demand for safety-related response.
S_StartResetBOOLFALSE
Start behaviour of safety FB
S_AutoResetBOOLFALSE
Behaviour on error of safety FB
ResetBOOLFALSE
Manual reset of FB
Output
ReadyBOOLFALSE
Activation of the FB. TRUE indicates that the FB is activated and the outputs results are valid, FALSE the FB is not active and the program is not executed.
S_ESPE_OutBOOLFALSE
Output for the safety-related response. FALSE: Safety output disabled. Demand for safety-related response (e.g., reset required or internal errors active). TRUE: Safety output enabled. No demand for safety-related re-sponse
SafetyDemandBOOLFALSE
Output indicating that the FB is active and the primary safety function is demanded (e.g. related to the safety functionality).
ResetRequestBOOLFALSE
Output which can be used to signal the operator to press the reset functionality to continue.
ErrorBOOLFALSE
Error flag
DiagCodeWORD0
Diagnostic register