SF_Antivalent (FB)ΒΆ
FUNCTION_BLOCK SF_Antivalent
- InOut:
Scope
Name
Type
Initial
Comment
Input
Activate
BOOL
FALSE
Activation of the FB.
S_ChannelNC
BOOL
FALSE
Input for NC (Normally Closed) connection. FALSE: NC contact open, TRUE: NC contact closed.
S_ChannelNO
BOOL
FALSE
Input for NO (Normally Open) connection. FALSE: NO contact open, TRUE: NO contact closed.
DiscrepancyTime
TIME
TIME#0ms
Maximum monitoring time for discrepancy status of both inputs
Output
Ready
BOOL
FALSE
Activation of the FB. TRUE indicates that the FB is activated and the outputs results are valid, FALSE the FB is not active and the program is not executed.
S_AntivalentOut
BOOL
FALSE
Safety related output
SafetyDemand
BOOL
FALSE
Output indicating that the FB is active and the primary safety function is demanded (e.g. related to the safety functionality).
Error
BOOL
FALSE
Error flag
DiagCode
WORD
0
Diagnostic register