FBS_ENSWITCH (ENUM)ΒΆ

TYPE FBS_ENSWITCH :

Definition of SF_EnableSwitch_2 function block states and its diagnostic values.

Attributes:
qualified_only
InOut:

Name

Initial

Comment

IDLE

16#0

The function block is not active (initial state).

BASIC_OPMODE

16#8002

Safe operation mode is not active.

SAFE_OPMODE

16#8004

Safe operation mode is active.

POSITION_1

16#8802

Safe operation mode is active and the enable switch is in position 1.

POSITION_3

16#8804

Safe operation mode is active and the enable switch is in position 3.

POSITION_2

16#8000

Safe operation mode is active and the enable switch is in position 2.

ERR_OPERATION_1

16#C010

Enable switch not in position 1 during activation of S_SafetyActive.

ERR_OPERATION_2

16#C020

Enable switch in position 1 after C010.

ERR_OPERATION_3

16#C030

Enable switch in position 2 after position 3.

ERR_OPERATION_4

16#C040

Enable switch not in position 2 after C030.

ERR_RESET_1

16#C001

Static Reset signal detected in state C020.

ERR_RESET_2

16#C011

Static Reset signal detected in state C040.