IBACnetStaticObjectBase (ITF)ΒΆ

INTERFACE PUBLIC IBACnetStaticObjectBase EXTENDS IBACnetObjectBase

Any BACnet-Object inserted as CODESYS-Device is reflected by an FB derived by this FB-Type. It establishes zhe correct initialization of the BACnet-Properties using the CODESYS-Devices Parameters.

Properties:

Methods:

GetBACnetAccumulatorRecordProperty, inherited from IBACnetObjectBase

GetBACnetBitStringProperty, inherited from IBACnetObjectBase

GetBACnetBooleanProperty, inherited from IBACnetObjectBase

GetBACnetClientCOVProperty, inherited from IBACnetObjectBase

GetBACnetDateProperty, inherited from IBACnetObjectBase

GetBACnetDateRangeProperty, inherited from IBACnetObjectBase

GetBACnetDateTimeProperty, inherited from IBACnetObjectBase

GetBACnetDevObjPropReferenceProperty, inherited from IBACnetObjectBase

GetBACnetEnumeratedProperty, inherited from IBACnetObjectBase

GetBACnetObjPropReferenceProperty, inherited from IBACnetObjectBase

GetBACnetObjectIDProperty, inherited from IBACnetObjectBase

GetBACnetPrescaleProperty, inherited from IBACnetObjectBase

GetBACnetRealProperty, inherited from IBACnetObjectBase

GetBACnetScaleProperty, inherited from IBACnetObjectBase

GetBACnetSetpointReferenceProperty, inherited from IBACnetObjectBase

GetBACnetSignedProperty, inherited from IBACnetObjectBase

GetBACnetStringProperty, inherited from IBACnetObjectBase

GetBACnetTimeProperty, inherited from IBACnetObjectBase

GetBACnetTimeStampProperty, inherited from IBACnetObjectBase

GetBACnetUnsignedProperty, inherited from IBACnetObjectBase

GetPropertyCallbackAttachment, inherited from IBACnetObjectBase

GetPropertyId, inherited from IBACnetObjectBase

GetPropertyInstance, inherited from IBACnetObjectBase

GetPropertyInstanceStackAllocContentBuffer, inherited from IBACnetObjectBase

GetPropertyInstanceWithContentBuffer, inherited from IBACnetObjectBase

IsPropertyExistent, inherited from IBACnetObjectBase

IsPropertyWriteable, inherited from IBACnetObjectBase

SetBACnetAccumulatorRecordProperty, inherited from IBACnetObjectBase

SetBACnetBitStringProperty, inherited from IBACnetObjectBase

SetBACnetBooleanProperty, inherited from IBACnetObjectBase

SetBACnetClientCOVProperty, inherited from IBACnetObjectBase

SetBACnetDateProperty, inherited from IBACnetObjectBase

SetBACnetDateRangeProperty, inherited from IBACnetObjectBase

SetBACnetDateTimeProperty, inherited from IBACnetObjectBase

SetBACnetDevObjPropReferenceProperty, inherited from IBACnetObjectBase

SetBACnetEnumeratedProperty, inherited from IBACnetObjectBase

SetBACnetObjPropReferenceProperty, inherited from IBACnetObjectBase

SetBACnetObjectIDProperty, inherited from IBACnetObjectBase

SetBACnetPrescaleProperty, inherited from IBACnetObjectBase

SetBACnetRealProperty, inherited from IBACnetObjectBase

SetBACnetScaleProperty, inherited from IBACnetObjectBase

SetBACnetSetpointReferenceProperty, inherited from IBACnetObjectBase

SetBACnetSignedProperty, inherited from IBACnetObjectBase

SetBACnetStringProperty, inherited from IBACnetObjectBase

SetBACnetTimeProperty, inherited from IBACnetObjectBase

SetBACnetTimeStampProperty, inherited from IBACnetObjectBase

SetBACnetUnsignedProperty, inherited from IBACnetObjectBase

SetObjectName, inherited from IBACnetObjectBase

SetPropertyAccessRight, inherited from IBACnetObjectBase

SetPropertyCallbackAttachment, inherited from IBACnetObjectBase

SetPropertyInstance, inherited from IBACnetObjectBase

WritePropertyInstance, inherited from IBACnetObjectBase

Structure: