Library Information
GetLibVersion (Function)
GetLibVersionNumber (Function)
GetVersion (Function)
IsLibReleased (Function)
SM3_Transformation
Function Blocks
Coupled Kinematics
Configuration
Kin_Coupled (FunctionBlock)
Kin_Empty (FunctionBlock)
AxesToCartesian (Method)
AxesToOrientation (Method)
CartesianToAxes (Method)
CartesianToAxes_Offset (Method)
GetAxisProperties (Method)
GetKinematicsName (Method)
GetOrientationImage (Method)
IsSingularity (Method)
NumAxes (Property)
ProjectPosition (Method)
Orientation Kinematics
CAxis_From_Orientation (Function)
Configuration
Kin_CAxis (FunctionBlock)
Kin_CAxis_Tool (FunctionBlock)
Kin_Tool (FunctionBlock)
Kin_Wrist2 (FunctionBlock)
Kin_Wrist3 (FunctionBlock)
Positioning Kinematics
Gantry Systems
Parallel Systems
Pos_RRR
Scara Systems
Standalone Kinematics
5 Axes
Articulated Robots
Scara Systems
Staubli
Functions
AXISLIMITS_Intersection (Function)
AXISPOS_REF_Eq (Function)
Coupled_GetAxisMapping (Function)
GetCombinedOrientationImage (Function)
GetFlangeOriImg (Function)
GetKinematicsForAxis (Function)
GetPeriods (Function)
Initialise_OriImage_dof0 (Function)
Initialise_OriImage_dof1 (Function)
Initialise_OriImage_dof3 (Function)
Kin_ApplyAxisSettings (Function)
OrientationSpace_Equals (Function)
ProjectRotation1dof (Function)
GlobalConstants
Constants (GVL)
Interfaces
ISMCoupledKinematics (Interface)
GetPosAndToolKinematics (Method)
ISMCoupledKinematics2 (Interface)
JoinAxes (Method)
JoinConfig (Method)
SplitAxes (Method)
SplitConfig (Method)
ISMCoupledKinematics3 (Interface)
GetAxisMapping (Method)
ISMCoupledKinematics4 (Interface)
GetAxisMapping2 (Method)
ISMKinPeriodHandling (Interface)
GetPeriods (Method)
ISMKinematicAxisSettings (Interface)
AxisSettings (Method)
ISMKinematicWithConfigurations (Interface)
GetConfigurationDataSize (Method)
GetDefaultConfigurationData (Method)
ISMKinematicWithConfigurations2 (Interface)
CPConnectible (Method)
ISMKinematicWithConfigurations3 (Interface)
ActivateAutomaticRotaryPeriods (Method)
ISMKinematicWithConfigurations4 (Interface)
IsConfigSingular (Method)
ISMKinematicWithInfo (Interface)
GetAxisProperties (Method)
IsSingularity (Method)
ISMKinematicWithInfo2 (Interface)
GetKinematicsName (Method)
ISMKinematicWithInitialization (Interface)
Initialize (Method)
IsInitialized (Method)
ISMKinematicsWithOrientationImage (Interface)
GetFlangeOrientationImage (Method)
ISMKinematicsWithOrientationImage2 (Interface)
GetFlangeOrientationImageTotal (Method)
GetFlangeOrientationImageWithOri (Method)
ISMOrientationKinematics (Interface)
GetPositionFromOrientation (Method)
ISMOrientationKinematics2 (Interface)
GetPositionFromOrientation2 (Method)
IsCompatibleWithPosKin (Method)
ISMOrientationKinematics3 (Interface)
GetPositionFromOrientation3 (Method)
ISMOrientationKinematicsWithOriImage (Interface)
GetOrientationImage (Method)
ISMOrientationKinematicsWithOriImage2 (Interface)
GetOrientationImageTotal (Method)
GetOrientationImageWithOri (Method)
ISMPositionKinematics (Interface)
AxesToOrientation (Method)
ISMPositionKinematics2 (Interface)
GetOrientationImage (Method)
ISMPositionKinematics_Offset (Interface)
CartesianToAxes_Offset (Method)
ISMPositionKinematics_Offset2 (Interface)
AxesToConfiguration_Offset (Method)
ISMToolKinematics (Interface)
ISMToolKinematics2 (Interface)
MC_KIN_REF_SM3 (Interface)
AxesToCartesian (Method)
CartesianToAxes (Method)
NumAxes (Property)
Structs
AXISLIMITS (Alias)
AXISPOS_REF (Struct)
Axis_Properties (Struct)
Axis_Settings (Alias)
Axis_Type (Enum)
CONFIGDATA (Struct)
Coupled_Kin_Axis_Map (Struct)
Coupled_Kin_Axis_Type (Enum)
MCS_OR_FLANGE (Enum)
OrientationDOF (Enum)
OrientationSpace (Struct)
File and Project Information
Library Reference
FloatingPointUtils
Library Identification
Library Properties
SM3_Error
Library Identification
Library Properties
SM3_Math
Library Identification
Library Properties
SM3_RBase
Library Identification
Library Properties
SM3_Shared
Library Identification
Library Properties
SM3_StringUtils
Library Identification
Library Properties
Standard
Library Identification
Library Properties
SysMem
Library Identification
Library Properties
SM3_Transformation
Docs
»
SM3_Transformation
»
Structs
»
AXISLIMITS (ALIAS)
AXISLIMITS (ALIAS)
ΒΆ
TYPE
AXISLIMITS
: SMRB.|dAXISLIMITS|