WriteAliasAddress (FB)ΒΆ
FUNCTION_BLOCK WriteAliasAddress EXTENDS ETrigA
This function block is for writing the memory of EtherCAT slaves.
- InOut:
- Scope - Name - Type - Initial - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError,- iError) are present at the outputs for exactly one cycle.- ETrigA - xAbort- BOOL- TRUE: Action is stopped immediately and all outputs are reset to their initial values.- ETrigA - Output - xDone- BOOL- TRUE: Action successfully completed- ETrigA - xBusy- BOOL- TRUE: Function block active- ETrigA - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrigA - xAborted- BOOL- TRUE: Action aborted by user- ETrigA - Input - usiCom- USINT- 1 - index of master 1: first Ethercat master - wSlaveAddress- WORD- address either auto increment address or physical address of device - xAutoIncAdr- BOOL- flag that determines which way to use the given address - uiAliasAddress- UINT- the alias address to be written - udiTimeOut- UDINT- Timeout for operation in ms