BACnetObjects¶
Function blocks and interfaces used for the device FBs corresponding to BACnet objects. These FBs get created automatically when inserting a BACnet device/object into the device tree.
- BACnetAccessCredential (FunctionBlock)
- AbsenteeLimit (Property)
- ActivationTime (Property)
- AssignedAccessRights (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- AuthenticationFactors (Property)
- AuthorizationExemptions (Property)
- BelongsTo (Property)
- CredentialDisable (Property)
- CredentialStatus (Property)
- DaysRemaining (Property)
- Description (Property)
- ExpirationTime (Property)
- ExtendedTimeEnable (Property)
- GlobalIdentifier (Property)
- LastAccessEvent (Property)
- LastAccessPoint (Property)
- LastUseTime (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- ReasonForDisable (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- ThreatAuthority (Property)
- TraceFlag (Property)
- UsesRemaining (Property)
- private
- BACnetAccessDoor (FunctionBlock)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- DoorAlarmState (Property)
- DoorExtendedPulseTime (Property)
- DoorMembers (Property)
- DoorOpenTooLongTime (Property)
- DoorPulseTime (Property)
- DoorStatus (Property)
- DoorUnlockDelayTime (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultValues (Property)
- LastCommandTime (Property)
- LockStatus (Property)
- MaintenanceRequired (Property)
- MaskedAlarmValues (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- SecuredStatus (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetAccessPoint (FunctionBlock)
- AccessAlarmEvents (Property)
- AccessDoors (Property)
- AccessEvent (Property)
- AccessEventAuthenticationFactor (Property)
- AccessEventCredential (Property)
- AccessEventTag (Property)
- AccessEventTime (Property)
- AccessTransactionEvents (Property)
- AccompanimentTime (Property)
- AckedTransitions (Property)
- ActiveAuthenticationPolicy (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- AuthenticationPolicyList (Property)
- AuthenticationPolicyNames (Property)
- AuthenticationStatus (Property)
- AuthorizationMode (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FailedAttemptEvents (Property)
- FailedAttempts (Property)
- FailedAttemptsTime (Property)
- Lockout (Property)
- LockoutRelinquishTime (Property)
- MaxFailedAttempts (Property)
- MusterPoint (Property)
- NotificationClass (Property)
- NotifyType (Property)
- NumberOfAuthenticationPolicies (Property)
- OccupancyCountAdjust (Property)
- OccupancyLowerLimitEnforced (Property)
- OccupancyUpperLimitEnforced (Property)
- OutOfService (Property)
- PriorityForWriting (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- ThreatLevel (Property)
- TransactionNotificationClass (Property)
- VerificationTime (Property)
- ZoneFrom (Property)
- ZoneTo (Property)
- private
- BACnetAccessRights (FunctionBlock)
- Accompaniment (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- Enable (Property)
- GlobalIdentifier (Property)
- NegativeAccessRules (Property)
- PositiveAccessRules (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- private
- BACnetAccessUser (FunctionBlock)
- AuditLevel (Property)
- AuditableOperations (Property)
- Credentials (Property)
- Description (Property)
- GlobalIdentifier (Property)
- MemberOf (Property)
- Members (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- UserExternalIdentifier (Property)
- UserInformationReference (Property)
- UserName (Property)
- UserType (Property)
- private
- BACnetAccessZone (FunctionBlock)
- AckedTransitions (Property)
- AdjustValue (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CredentialsInZone (Property)
- Description (Property)
- EntryPoints (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- ExitPoints (Property)
- GlobalIdentifier (Property)
- LastCredentialAdded (Property)
- LastCredentialAddedTime (Property)
- LastCredentialRemoved (Property)
- LastCredentialRemovedTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OccupancyCount (Property)
- OccupancyCountEnable (Property)
- OccupancyLowerLimit (Property)
- OccupancyState (Property)
- OccupancyUpperLimit (Property)
- OutOfService (Property)
- PassbackMode (Property)
- PassbackTimeout (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- private
- BACnetAccumulator (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- DeviceType (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultHighLimit (Property)
- FaultLowLimit (Property)
- HighLimit (Property)
- LimitEnable (Property)
- LimitMonitoringInterval (Property)
- LoggingObject (Property)
- LoggingRecord (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- Prescale (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- PulseRate (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- Scale (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- ValueBeforeChange (Property)
- ValueChangeTime (Property)
- ValueSet (Property)
- BACnetAlertEnrollment (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- NotificationClass (Property)
- NotifyType (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Tags (Property)
- BACnetAnalogInput (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- Deadband (Property)
- Description (Property)
- DeviceType (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultHighLimit (Property)
- FaultLowLimit (Property)
- HighLimit (Property)
- InterfaceValue (Property)
- LimitEnable (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- Resolution (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- UpdateInterval (Property)
- BACnetAnalogOutput (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Deadband (Property)
- Description (Property)
- DeviceType (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- HighLimit (Property)
- InterfaceValue (Property)
- LastCommandTime (Property)
- LimitEnable (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- Resolution (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetAnalogValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Deadband (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultHighLimit (Property)
- FaultLowLimit (Property)
- HighLimit (Property)
- LastCommandTime (Property)
- LimitEnable (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- Resolution (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetAuditLog (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- BufferSize (Property)
- DeleteOnForward (Property)
- Description (Property)
- Enable (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IssueConfirmedNotifications (Property)
- MemberOf (Property)
- NotificationClass (Property)
- NotifyType (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RecordCount (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- TotalRecordCount (Property)
- BACnetAuditReporter (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditSourceReporter (Property)
- AuditableOperations (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IssueConfirmedNotifications (Property)
- MaximumSendDelay (Property)
- MonitoredObjects (Property)
- NotificationClass (Property)
- NotifyType (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- SendNow (Property)
- StatusFlags (Property)
- Tags (Property)
- private
- BACnetAveraging (FunctionBlock)
- AttemptedSamples (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- AverageValue (Property)
- Description (Property)
- MaximumValue (Property)
- MaximumValueTimestamp (Property)
- MinimumValue (Property)
- MinimumValueTimestamp (Property)
- ObjectPropertyReference (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Tags (Property)
- ValidSamples (Property)
- VarianceValue (Property)
- WindowInterval (Property)
- WindowSamples (Property)
- BACnetBinaryInput (FunctionBlock)
- AckedTransitions (Property)
- ActiveText (Property)
- AlarmValue (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- ChangeOfStateCount (Property)
- ChangeOfStateTime (Property)
- Description (Property)
- DeviceType (Property)
- ElapsedActiveTime (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- InactiveText (Property)
- InterfaceValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- Polarity (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- TimeOfActiveTimeReset (Property)
- TimeOfStateCountReset (Property)
- BACnetBinaryLightingOutput (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- BlinkWarnEnable (Property)
- ColorOverride (Property)
- ColorReference (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EgressActive (Property)
- EgressTime (Property)
- ElapsedActiveTime (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FeedbackValue (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- OverrideColorReference (Property)
- Polarity (Property)
- Power (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- StrikeCount (Property)
- Tags (Property)
- TimeOfActiveTimeReset (Property)
- TimeOfStrikeCountReset (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetBinaryOutput (FunctionBlock)
- AckedTransitions (Property)
- ActiveText (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- ChangeOfStateCount (Property)
- ChangeOfStateTime (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- DeviceType (Property)
- ElapsedActiveTime (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FeedbackValue (Property)
- InactiveText (Property)
- InterfaceValue (Property)
- LastCommandTime (Property)
- MinimumOffTime (Property)
- MinimumOnTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- Polarity (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- TimeOfActiveTimeReset (Property)
- TimeOfStateCountReset (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetBinaryValue (FunctionBlock)
- AckedTransitions (Property)
- ActiveText (Property)
- AlarmValue (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- ChangeOfStateCount (Property)
- ChangeOfStateTime (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- ElapsedActiveTime (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- InactiveText (Property)
- LastCommandTime (Property)
- MinimumOffTime (Property)
- MinimumOnTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- TimeOfActiveTimeReset (Property)
- TimeOfStateCountReset (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetBitStringValue (FunctionBlock)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- BitMask (Property)
- BitText (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetCalendar (FunctionBlock)
- BACnetChannel (FunctionBlock)
- AckedTransitions (Property)
- AllowGroupDelayInhibit (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- ChannelNumber (Property)
- ControlGroups (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- ExecutionDelay (Property)
- LastPriority (Property)
- NotificationClass (Property)
- NotifyType (Property)
- ObjectPropertyReferences (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- WriteStatus (Property)
- private
- BACnetCharacterStringValue (FunctionBlock)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultValues (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetColor (FunctionBlock)
- AuditLevel (Property)
- AuditableOperations (Property)
- ColorCommand (Property)
- DefaultColor (Property)
- DefaultFadeTime (Property)
- Description (Property)
- InProgress (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Tags (Property)
- TrackingValue (Property)
- Transition (Property)
- ValueSource (Property)
- BACnetColorTemperature (FunctionBlock)
- AuditLevel (Property)
- AuditableOperations (Property)
- ColorCommand (Property)
- DefaultColorTemperature (Property)
- DefaultFadeTime (Property)
- DefaultRampRate (Property)
- DefaultStepIncrement (Property)
- Description (Property)
- InProgress (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Tags (Property)
- TrackingValue (Property)
- Transition (Property)
- ValueSource (Property)
- BACnetCommand (FunctionBlock)
- AckedTransitions (Property)
- ActionProperty (Property)
- ActionText (Property)
- AllWritesSuccessful (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- InProcess (Property)
- InitializeActionCommands
- NotificationClass (Property)
- NotifyType (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- private
- BACnetCredentialDataInput (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- SupportedFormatClasses (Property)
- SupportedFormats (Property)
- Tags (Property)
- UpdateTime (Property)
- private
- BACnetDatePatternValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetDateTimePatternValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IsUTC (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetDateTimeValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IsUTC (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetDateValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetDevice (FunctionBlock)
- APDUSegmentTimeout (Property)
- APDUTimeout (Property)
- AckedTransitions (Property)
- ActiveCOVMultipleSubscriptions (Property)
- ActiveCOVSubscriptions (Property)
- ActiveVTSessions (Property)
- AlignIntervals (Property)
- ApplicationSoftwareVersion (Property)
- AuditLevel (Property)
- AuditNotificationRecipient (Property)
- AuditableOperations (Property)
- BackupAndRestoreState (Property)
- BackupFailureTimeout (Property)
- BackupPreparationTime (Property)
- ConfigurationFiles (Property)
- DatabaseRevision (Property)
- DaylightSavingsStatus (Property)
- DeployedProfileLocation (Property)
- Description (Property)
- DeviceAddressBinding (Property)
- DeviceUUID (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FirmwareRevision (Property)
- IntervalOffset (Property)
- LastRestartReason (Property)
- LastRestoreTime (Property)
- LocalDate (Property)
- LocalTime (Property)
- Location (Property)
- MaxAPDULengthAccepted (Property)
- MaxInfoFrames (Property)
- MaxManager (Property)
- MaxSegmentsAccepted (Property)
- ModelName (Property)
- NotificationClass (Property)
- NotifyType (Property)
- NumberOfAPDURetries (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- ProtocolObjectTypesSupported (Property)
- ProtocolRevision (Property)
- ProtocolServicesSupported (Property)
- ProtocolVersion (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RestartNotificationRecipients (Property)
- RestoreCompletionTime (Property)
- RestorePreparationTime (Property)
- SegmentationSupported (Property)
- SerialNumber (Property)
- StatusFlags (Property)
- StructuredObjectList (Property)
- SystemStatus (Property)
- Tags (Property)
- TimeOfDeviceRestart (Property)
- TimeSynchronizationInterval (Property)
- TimeSynchronizationRecipients (Property)
- UTCOffset (Property)
- UTCTimeSynchronizationRecipients (Property)
- VTClassesSupported (Property)
- VendorIdentifier (Property)
- VendorName (Property)
- BACnetElevatorGroup (FunctionBlock)
- BACnetEscalator (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- ElevatorGroup (Property)
- EnergyMeter (Property)
- EnergyMeterRef (Property)
- EscalatorMode (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultSignals (Property)
- GroupID (Property)
- InstallationID (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OperationDirection (Property)
- OutOfService (Property)
- PassengerAlarm (Property)
- PowerMode (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- private
- BACnetEventEnrollment (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventParameters (Property)
- EventState (Property)
- EventTimeStamps (Property)
- EventType (Property)
- FaultParameters (Property)
- FaultType (Property)
- NotificationClass (Property)
- NotifyType (Property)
- ObjectPropertyReference (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelayNormal (Property)
- private
- BACnetEventLog (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- BufferSize (Property)
- Description (Property)
- Enable (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- LastNotifyRecord (Property)
- NotificationClass (Property)
- NotificationThreshold (Property)
- NotifyType (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RecordCount (Property)
- RecordsSinceNotification (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StartTime (Property)
- StatusFlags (Property)
- StopTime (Property)
- StopWhenFull (Property)
- Tags (Property)
- TotalRecordCount (Property)
- BACnetFile (FunctionBlock)
- Archive (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- FileAccessMethod (Property)
- FileSize (Property)
- FileType (Property)
- ModificationDate (Property)
- PLCLocalFileName (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- ReadOnly (Property)
- RecordCount (Property)
- Tags (Property)
- BACnetGlobalGroup (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- COVResubscriptionInterval (Property)
- COVUPeriod (Property)
- COVURecipients (Property)
- ClientCOVIncrement (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- GroupMemberNames (Property)
- GroupMembers (Property)
- MemberStatusFlags (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RequestedUpdateInterval (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- UpdateInterval (Property)
- private
- BACnetGroup (FunctionBlock)
- BACnetIntegerValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Deadband (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultHighLimit (Property)
- FaultLowLimit (Property)
- HighLimit (Property)
- LastCommandTime (Property)
- LimitEnable (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- Resolution (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetLargeAnalogValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Deadband (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultHighLimit (Property)
- FaultLowLimit (Property)
- HighLimit (Property)
- LastCommandTime (Property)
- LimitEnable (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- Resolution (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetLifeSafetyPoint (FunctionBlock)
- AcceptedModes (Property)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- DeviceType (Property)
- DirectReading (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultValues (Property)
- FloorNumber (Property)
- LifeSafetyAlarmValues (Property)
- MaintenanceRequired (Property)
- MemberOf (Property)
- Mode (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OperationExpected (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- Setting (Property)
- Silenced (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- TrackingValue (Property)
- Units (Property)
- ValueSource (Property)
- private
- BACnetLifeSafetyZone (FunctionBlock)
- AcceptedModes (Property)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- DeviceType (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultValues (Property)
- FloorNumber (Property)
- LifeSafetyAlarmValues (Property)
- MaintenanceRequired (Property)
- MemberOf (Property)
- Mode (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OperationExpected (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- Silenced (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- TrackingValue (Property)
- ValueSource (Property)
- ZoneMembers (Property)
- private
- BACnetLift (FunctionBlock)
- AckedTransitions (Property)
- AssignedLandingCalls (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CarAssignedDirection (Property)
- CarDoorCommand (Property)
- CarDoorStatus (Property)
- CarDoorText (Property)
- CarDoorZone (Property)
- CarDriveStatus (Property)
- CarLoad (Property)
- CarLoadUnits (Property)
- CarMode (Property)
- CarMovingDirection (Property)
- CarPosition (Property)
- Description (Property)
- ElevatorGroup (Property)
- EnergyMeter (Property)
- EnergyMeterRef (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultSignals (Property)
- FloorText (Property)
- GroupID (Property)
- HigherDeck (Property)
- InstallationID (Property)
- LandingDoorStatus (Property)
- LowerDeck (Property)
- MakingCarCall (Property)
- NextStoppingFloor (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PassengerAlarm (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RegisteredCarCall (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- private
- BACnetLightingOutput (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- BlinkWarnEnable (Property)
- COVIncrement (Property)
- ColorOverride (Property)
- ColorReference (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- DefaultFadeTime (Property)
- DefaultRampRate (Property)
- DefaultStepIncrement (Property)
- Description (Property)
- EgressActive (Property)
- EgressTime (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FeedbackValue (Property)
- HighEndTrim (Property)
- InProgress (Property)
- InstantaneousPower (Property)
- LastCommandTime (Property)
- LightingCommand (Property)
- LightingCommandDefaultPriority (Property)
- LowEndTrim (Property)
- MaxActualValue (Property)
- MinActualValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- OverrideColorReference (Property)
- Power (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- TrackingValue (Property)
- Transition (Property)
- TrimFadeTime (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetLoadControl (FunctionBlock)
- AckedTransitions (Property)
- ActualShedLevel (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- DutyWindow (Property)
- Enable (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- ExpectedShedLevel (Property)
- FullDutyBaseline (Property)
- NotificationClass (Property)
- NotifyType (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RequestedShedLevel (Property)
- ShedDuration (Property)
- ShedLevelDescriptions (Property)
- ShedLevels (Property)
- StartTime (Property)
- StateDescription (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- ValueSource (Property)
- private
- BACnetLoop (FunctionBlock)
- AckedTransitions (Property)
- ActionProperty (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Bias (Property)
- COVIncrement (Property)
- CompatibilityAliases
- ControlledVariableReference (Property)
- ControlledVariableUnits (Property)
- ControlledVariableValue (Property)
- Deadband (Property)
- DerivativeConstant (Property)
- DerivativeConstantUnits (Property)
- Description (Property)
- ErrorLimit (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IntegralConstant (Property)
- IntegralConstantUnits (Property)
- LowDiffLimit (Property)
- ManipulatedVariableReference (Property)
- MaximumOutput (Property)
- MinimumOutput (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- OutputUnits (Property)
- PresentValue (Property)
- PriorityForWriting (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- ProportionalConstant (Property)
- ProportionalConstantUnits (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- Setpoint (Property)
- SetpointReference (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- UpdateInterval (Property)
- BACnetMultistateInput (FunctionBlock)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- DeviceType (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultValues (Property)
- InterfaceValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- NumberOfStates (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StateText (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- private
- BACnetMultistateOutput (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- DeviceType (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FeedbackValue (Property)
- InterfaceValue (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- NumberOfStates (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StateText (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetMultistateValue (FunctionBlock)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultValues (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- NumberOfStates (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StateText (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetNetworkPort (FunctionBlock)
- APDULength (Property)
- AckedTransitions (Property)
- AutoSubordinateDiscovery (Property)
- BACnetIPGlobalAddress (Property)
- BACnetIPMode (Property)
- BACnetIPMulticastAddress (Property)
- BACnetIPNATTraversal (Property)
- BACnetIPUDPPort (Property)
- BBMDAcceptFDRegistrations (Property)
- BBMDBroadcastDistributionTable (Property)
- BBMDForeignDeviceTable (Property)
- ChangesPending (Property)
- Command (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FDBBMDAddress (Property)
- FDSubscriptionLifetime (Property)
- IPAddress (Property)
- IPDHCPEnable (Property)
- IPDHCPLeaseTime (Property)
- IPDHCPLeaseTimeRemaining (Property)
- IPDHCPServer (Property)
- IPDNSServer (Property)
- IPDefaultGateway (Property)
- IPSubnetMask (Property)
- MACAddress (Property)
- ManualSubordinateAddressBinding (Property)
- MaxInfoFrames (Property)
- MaxManager (Property)
- NetworkNumber (Property)
- NetworkNumberQuality (Property)
- NetworkType (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- ProtocolLevel (Property)
- ReferencePort (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RoutingTable (Property)
- StatusFlags (Property)
- SubordinateAddressBinding (Property)
- SubordinateProxyEnable (Property)
- Tags (Property)
- private
- BACnetNotificationClass (FunctionBlock)
- AckRequired (Property)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- NotificationClass (Property)
- NotifyType (Property)
- Priority (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RecipientList (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- private
- BACnetNotificationForwarder (FunctionBlock)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- LocalForwardingOnly (Property)
- OutOfService (Property)
- PortFilter (Property)
- ProcessIdentifierFilter (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RecipientList (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- SubscribedRecipients (Property)
- Tags (Property)
- private
- BACnetOctetStringValue (FunctionBlock)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventState (Property)
- LastCommandTime (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetPositiveIntegerValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditPriorityFilter (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Deadband (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- FaultHighLimit (Property)
- FaultLowLimit (Property)
- HighLimit (Property)
- LastCommandTime (Property)
- LimitEnable (Property)
- LowLimit (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- Resolution (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- WritePresentValueNullWithPriority (Method)
- WritePresentValueWithPriority (Method)
- private
- BACnetProgram (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- DescriptionOfHalt (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- InstanceOf (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- ProgramChange (Property)
- ProgramLocation (Property)
- ProgramState (Property)
- ReasonForHalt (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StatusFlags (Property)
- Tags (Property)
- BACnetPulseConverter (FunctionBlock)
- AckedTransitions (Property)
- AdjustValue (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- COVPeriod (Property)
- Count (Property)
- CountBeforeChange (Property)
- CountChangeTime (Property)
- Deadband (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- HighLimit (Property)
- InputReference (Property)
- LimitEnable (Property)
- LowLimit (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- ScaleFactor (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- Units (Property)
- UpdateTime (Property)
- BACnetSchedule (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- Description (Property)
- EffectivePeriod (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- ExceptionSchedule (Property)
- NotificationClass (Property)
- NotifyType (Property)
- ObjectPropertyReferences (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityForWriting (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- ScheduleDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- WeeklySchedule (Property)
- WriteEveryScheduledAction (Property)
- obsolete
- private
- BACnetStaging (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- COVIncrement (Property)
- DefaultPresentValue (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentStage (Property)
- PresentValue (Property)
- PriorityForWriting (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StageNames (Property)
- Stages (Property)
- StatusFlags (Property)
- Tags (Property)
- TargetReferences (Property)
- Units (Property)
- ValueSource (Property)
- private
- BACnetStructuredView (FunctionBlock)
- AuditLevel (Property)
- AuditableOperations (Property)
- DefaultSubordinateRelationship (Property)
- Description (Property)
- NodeSubtype (Property)
- NodeType (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Represents (Property)
- SubordinateAnnotations (Property)
- SubordinateList (Property)
- SubordinateNodeTypes (Property)
- SubordinateRelationships (Property)
- SubordinateTags (Property)
- Tags (Property)
- private
- BACnetTimePatternValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetTimeValue (FunctionBlock)
- AckedTransitions (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- CommandTimeArray (Property)
- CurrentCommandPriority (Property)
- Description (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- LastCommandTime (Property)
- NotificationClass (Property)
- NotifyType (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityArray (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- RelinquishDefault (Property)
- StatusFlags (Property)
- Tags (Property)
- ValueSource (Property)
- ValueSourceArray (Property)
- private
- BACnetTimer (FunctionBlock)
- AckedTransitions (Property)
- AlarmValues (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- DefaultTimeout (Property)
- Description (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- ExpirationTime (Property)
- InitialTimeout (Property)
- LastStateChange (Property)
- MaxPresValue (Property)
- MinPresValue (Property)
- NotificationClass (Property)
- NotifyType (Property)
- ObjectPropertyReferences (Property)
- OutOfService (Property)
- PresentValue (Property)
- PriorityForWriting (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- Resolution (Property)
- StateChangeValues (Property)
- StatusFlags (Property)
- Tags (Property)
- TimeDelay (Property)
- TimeDelayNormal (Property)
- TimerRunning (Property)
- TimerState (Property)
- UpdateTime (Property)
- private
- BACnetTrendLog (FunctionBlock)
- AckedTransitions (Property)
- AlignIntervals (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- BufferSize (Property)
- COVResubscriptionInterval (Property)
- ClientCOVIncrement (Property)
- Description (Property)
- Enable (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IntervalOffset (Property)
- LastNotifyRecord (Property)
- LogDeviceObjectProperty (Property)
- LogInterval (Property)
- LoggingType (Property)
- NotificationClass (Property)
- NotificationThreshold (Property)
- NotifyType (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RecordCount (Property)
- RecordsSinceNotification (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StartTime (Property)
- StatusFlags (Property)
- StopTime (Property)
- StopWhenFull (Property)
- Tags (Property)
- TotalRecordCount (Property)
- Trigger (Property)
- BACnetTrendLogMultiple (FunctionBlock)
- AckedTransitions (Property)
- AlignIntervals (Property)
- AuditLevel (Property)
- AuditableOperations (Property)
- BufferSize (Property)
- Description (Property)
- Enable (Property)
- EventAlgorithmInhibit (Property)
- EventAlgorithmInhibitRef (Property)
- EventDetectionEnable (Property)
- EventEnable (Property)
- EventMessageTexts (Property)
- EventMessageTextsConfig (Property)
- EventState (Property)
- EventTimeStamps (Property)
- IntervalOffset (Property)
- LastNotifyRecord (Property)
- LogDeviceObjectProperty (Property)
- LogInterval (Property)
- LoggingType (Property)
- NotificationClass (Property)
- NotificationThreshold (Property)
- NotifyType (Property)
- ProfileLocation (Property)
- ProfileName (Property)
- RecordCount (Property)
- RecordsSinceNotification (Property)
- Reliability (Property)
- ReliabilityEvaluationInhibit (Property)
- StartTime (Property)
- StatusFlags (Property)
- StopTime (Property)
- StopWhenFull (Property)
- Tags (Property)
- TotalRecordCount (Property)
- Trigger (Property)
- private
- base
- BACnetObjectBase (FunctionBlock)
- DeviceInstNumber (Property)
- GetPropertyAccessRight (Method)
- GetPropertyCallbackAttachment (Method)
- GetPropertyId (Method)
- GetPropertyInstanceStackAllocContentBuffer (Method)
- GetPropertyInstanceWithContentBuffer (Method)
- IsPropertyExistent (Method)
- IsPropertyWriteable (Method)
- NumberOfProperties (Property)
- ObjectID (Property)
- ObjectName (Property)
- SetObjectName (Method)
- SetPropertyAccessRight (Method)
- SetPropertyCallbackAttachment (Method)
- SetPropertyInstance (Method)
- Utilities
- typed property access
- GetBACnetAccumulatorRecordProperty (Method)
- GetBACnetArraySizeOfProperty (Method)
- GetBACnetBitStringProperty (Method)
- GetBACnetBooleanProperty (Method)
- GetBACnetClientCOVProperty (Method)
- GetBACnetColorCommandProperty (Method)
- GetBACnetDateProperty (Method)
- GetBACnetDateRangeProperty (Method)
- GetBACnetDateTime2Property (Method)
- GetBACnetDateTimeProperty (Method)
- GetBACnetDevObjPropReferenceProperty (Method)
- GetBACnetDevObjReferenceProperty (Method)
- GetBACnetDoubleProperty (Method)
- GetBACnetEnumeratedProperty (Method)
- GetBACnetLightingCommandProperty (Method)
- GetBACnetObjPropReferenceProperty (Method)
- GetBACnetObjectIDProperty (Method)
- GetBACnetOptionalEnumeratedProperty (Method)
- GetBACnetOptionalPriorityFilterProperty (Method)
- GetBACnetOptionalREALProperty (Method)
- GetBACnetOptionalUnsignedProperty (Method)
- GetBACnetPrescaleProperty (Method)
- GetBACnetProcessIdSelectionProperty (Method)
- GetBACnetRealProperty (Method)
- GetBACnetRecipientProperty (Method)
- GetBACnetScaleProperty (Method)
- GetBACnetSetpointReferenceProperty (Method)
- GetBACnetShedLevelProperty (Method)
- GetBACnetSignedProperty (Method)
- GetBACnetStringProperty (Method)
- GetBACnetTime2Property (Method)
- GetBACnetTimeProperty (Method)
- GetBACnetTimeStampProperty (Method)
- GetBACnetUnsignedProperty (Method)
- GetBACnetValueSourceProperty (Method)
- GetBACnetxyColorProperty (Method)
- IsBACnetDateTimePropertyUnspecified (Method)
- SetBACnetAccumulatorRecordProperty (Method)
- SetBACnetArraySizeOfProperty (Method)
- SetBACnetBitStringProperty (Method)
- SetBACnetBooleanProperty (Method)
- SetBACnetClientCOVProperty (Method)
- SetBACnetColorCommandProperty (Method)
- SetBACnetDateProperty (Method)
- SetBACnetDateRangeProperty (Method)
- SetBACnetDateTime2Property (Method)
- SetBACnetDateTimeProperty (Method)
- SetBACnetDateTimePropertyToUnspecified (Method)
- SetBACnetDevObjPropReferenceProperty (Method)
- SetBACnetDevObjReferenceProperty (Method)
- SetBACnetDoubleProperty (Method)
- SetBACnetEnumeratedProperty (Method)
- SetBACnetLightingCommandProperty (Method)
- SetBACnetObjPropReferenceProperty (Method)
- SetBACnetObjectIDProperty (Method)
- SetBACnetOctetStringProperty (Method)
- SetBACnetOptionalEnumeratedProperty (Method)
- SetBACnetOptionalPriorityFilterProperty (Method)
- SetBACnetOptionalREALProperty (Method)
- SetBACnetOptionalUnsignedProperty (Method)
- SetBACnetPrescaleProperty (Method)
- SetBACnetProcessIdSelectionProperty (Method)
- SetBACnetRealProperty (Method)
- SetBACnetRecipientProperty (Method)
- SetBACnetScaleProperty (Method)
- SetBACnetSetpointReferenceProperty (Method)
- SetBACnetShedLevelProperty (Method)
- SetBACnetSignedProperty (Method)
- SetBACnetStringProperty (Method)
- SetBACnetTime2Property (Method)
- SetBACnetTimeProperty (Method)
- SetBACnetTimeStampProperty (Method)
- SetBACnetUnsignedProperty (Method)
- SetBACnetValueSourceProperty (Method)
- SetBACnetxyColorProperty (Method)
- typed property access
- WritePropertyInstance (Method)
- private
- IBACnetStaticObjectBase (Interface)
- BACnetObjectBase (FunctionBlock)