ScriptSymbolConfigObject

class ScriptSymbolConfigObject.DirectIoAccessObstacles(value, names=None, *, module=None, qualname=None, type=None, start=1, boundary=None)

Bases: Enum

This enum shows the obstacles which prevent the Direct IO access from taking place.

none = (0,)

Direct I/O access is possible.

OldCompilerVersion = (1,)

The compiler version is to old.

TargetSettingSeparateApplication = (2,)

The symbol configuration is configured as a child object.

class ScriptSymbolConfigObject.SymbolConfigContentFeatureFlags(value, names=None, *, module=None, qualname=None, type=None, start=1, boundary=None)

Bases: Enum

The feature flags describing the contents of the symbol tables and XML files. (Introduced in V3.5.8.30, more broadly supported in V3.5.9.0.)

Remark: The “runtime” part of this enum is also defined in the “ContentFeatureFlags” enumeration in the IecVarAccess Interfaces library.

none = (0,)

Nothing configured.

MaskRuntime = (65535,)

The runtime feature bit mask (also relevant for CRC calculation).

MaskXml = (4294901760,)

The XML feature bit mask (not relevant for CRC calculation).

SupportOPCUA = (1,)

Support OPC UA features (flag supported since V3.5.8.30). This is equal to the <see cref=”ISymbolConfigObject6.SupportOPCUA”/> property. Remark: This is required for <see cref=”IncludeComments”/>, <see cref=”IncludeAttributes”/> and <see cref=”IncludeTypeNodeAttributes”/>. In compiler versions V3.5.5.0 to V3.5.7.X, this implied <see cref=”IncludeAttributes”/> with a filter matching only single IEC identifiers. In compiler versions V3.5.8.X, this implied <see cref=”IncludeAttributes”/> with a filter matching IEC identifier pathes (e. G. foo.bar.baz).

IncludeComments = (2,)

Include comments (flag supported since V3.5.9.0).

IncludeAttributes = (4,)

Include attributes (flag supported since V3.5.9.0).

IncludeTypeNodeAttributes = (8,)

Also include comments / attributes for type nodes (flag supported since V3.5.9.0).

IncludeExecutables = (16,)

Inclusion of executable members (flag supported since V3.5.11.0, allows calling of programs, functions, FBs and methods, requires OPC UA). Remark: If this flag is set, the list of available signatures will also include callables.

UseEmptyNamespaceByDefault = (32,)

Assumes that effectively every POU has the {attribute ‘namespace’:=’’} set. This is required to preserve compatibility to V2 symbol definitions.

XmlIncludeNodeFlags = (65536,)

Include the node flags in the XML file (flag supported since V3.5.8.30). Remark: This was implied in compiler version V3.5.8.0, and is configurable using this flag since V3.5.8.30 due to backwards compatibility problems with various XML parsers.

XmlIncludeComments = (131072,)

Include comments in the XML file (flag supported since V3.5.8.30), equal to <see cref=”ISymbolConfigObject5.ExportCommentsInXML”/> flag. Remark: In compiler versions 3.5.5.X to 3.5.8.X, this implied <see cref=”SymbolCommentFilterType.PreferDocuComments”/>.

XmlIncludeAttributes = (262144,)

Include the attributes in XML (flag supported since V3.5.9.0).

XmlIncludeTypeNodeAttributes = (524288,)

Also include comments / attributes for type nodes (flag supported since V3.5.9.0).

XmlIncludeExecutables = (1048576,)

Inclusion of executable members (flag supported since V3.5.11.0, allows calling of programs, functions, FBs and methods, requires OPC UA). Remark: This requires <see cref=”IncludeExecutables”/> to be active - settingt his flag to false allows to suppress the executables in the for backwards compatibility.

class ScriptSymbolConfigObject.SymbolAttributeFilterTypes(value, names=None, *, module=None, qualname=None, type=None, start=1, boundary=None)

Bases: Enum

Definition of the attribute matching type

none = (0,)

No attributes or not configured.

All = (1,)

All attributes are included.

SimpleIdentifiers = (2,)

Match all simple identifiers without fullstop (non-hierarchical attributes). Remark: This is mainly here for backwards compatibility.

Prefix = (3,)

Prefix matching of attributes

Regex = (4,)

Regex matching of attributes

class ScriptSymbolConfigObject.SymbolCommentFilterType(value, names=None, *, module=None, qualname=None, type=None, start=1, boundary=None)

Bases: Enum

Defines which comments are included in the XML file or symbol tables.

none = (0,)

No comments are included at all, or not configured.

NormalComments = (1,)

Only normal comments are included, those delimited with // or (* *).

DocuComments = (2,)

Only docu comments are included, those delimited with ///.

Both = (3,)

Include both normal and docu comments. This is the default, currently. Remark: This is equal to combining <see cref=”NormalComments”/> and <see cref=”DocuComments”/>.

PreferNormalComments = (4,)

Prefer the normal comments, docu comment is used when no normal comment is there. Remark: This implies <see cref=”NormalComments”/> and <see cref=”DocuComments”/>.

PreferDocuComments = (5,)

Prefer the docu comments, normal comment is used when docu comment is not there. Remark: This implies <see cref=”NormalComments”/> and <see cref=”DocuComments”/>.

class ScriptSymbolConfigObject.ScriptSymbolConfigObjectMarker

Bases: object

Every ScriptObject instance will be extended with this method.

Version added:

3.5.10.0

property is_symbol_config

Gets a value indicating whether this instance is a symbol config object.

Return type:

bool

Returns:

True if this instance is symbol config object, otherwise False.

class ScriptSymbolConfigObject.ScriptSymbolConfigObject

Bases: ScriptSymbolConfigObjectMarker

Functionality for manipulating symbol configuration objects.

Version added:

3.5.10.0

property client_side_layout_calculator_guid

Gets or sets the Guid denoting the currently configured client side layout calculator.

Currently, two different values are allowed: Guid.Empty to use the Compatibility Offset Calculator which is always available. And “{0141eb75-141b-4ea1-9a8c-75f952b22a6c}” to use the OptimizedOutputOffsetCalculator which is new with V3.5.7.0 and also requires the compiler version 3.5.7.0 (see http://jira.3s-software.com/browse/CDS-41816). This scheme may be extended to allow more or even arbitrary offset calculators in the future.

Return type:

Guid

property client_side_layout_calculator

Gets or sets the calculator object denoting the currently configured client side layout calculator.

Currently, two different values are allowed: Guid.Empty to use the Compatibility Offset Calculator which is always available. And “{0141eb75-141b-4ea1-9a8c-75f952b22a6c}” to use the OptimizedOutputOffsetCalculator which is new with V3.5.7.0 and also requires the compiler version 3.5.7.0 (see http://jira.3s-software.com/browse/CDS-41816). This scheme may be extended to allow more or even arbitrary offset calculators in the future.

Return type:

ScriptClientSideLayoutCalculatorDescription

property available_client_side_layout_calculators

Gets all currently known layout calculators.

Return type:

ScriptClientSideLayoutCalculatorDescriptionCollection

property enable_direct_io_access

Gets or sets a boolean whether direct Access to the I/O Area is configured.

Enabling direct access to the I/O area is supported for debugging purposes, e. G. testing the cables and connections. It is not meant for productive operation. It is only available under certain conditions, e. G. the compiler version must be >= V3.5.8.0 and the symbol config must not be generated as a child application.

Return type:

bool

check_effective_direct_io_access()

Checks whether and why the direct Access to the I/O Area is effectively enabled / disabled.

Enabling direct access to the I/O area is supported for debugging purposes, e. G. testing the cables and connections. It is not meant for productive operation. It is only available under certain conditions, e. G. the compiler version must be &gt;= V3.5.8.0 and the symbol config must not be generated as a child application.

Return type:

DirectIoAccessObstacles

Returns:

The DirectIoAccessObstacles flag describing which reasons prevent the Direct IO Access from being enabled.

get_direct_io_obstacle_explanations(obstacles)

Gets user readable, localized messages / explanations of the obstacles.

Parameters:

obstacles (DirectIoAccessObstacles) – The obstacles.

Return type:

list[str]

Returns:

A list of strings with one entry for each obstacle, or an “is enabled” message when obstacles == DirectIoAccessObstacles.None.

property content_feature_flags

The configured content feature flags. This is partially redundant with SymbolConfigObject.ExportCommentsInXML and SymbolConfigObject.SupportOPCUA.

Return type:

SymbolConfigContentFeatureFlags

property effective_content_feature_flags

The effective content feature flags, considering the content_feature_flags and the compiler version setting.

Return type:

SymbolConfigContentFeatureFlags

get_symbol_configuration_xsd()

Gets the current symbol configuration XML schema, as appropriate for the current symbol config object.

The schema is delivered as a byte array, containing the UTF-8 encoded XSD file as it is also published in the http://www.3s-software.com/schemas/Symbolconfiguration.xsd. The above URL aways points to the newest released version of the schema, while the get_symbol_configuration_xsd() property delivers the XSD file applicable to the current release of the SymbolConfig plugin.

Return type:

list[byte]

Returns:

The current symbol configuration XML schema as byte array.

property symbol_attribute_filter_type

The configured filter type for the attributes.

Return type:

SymbolAttributeFilterTypes

property effective_symbol_attribute_filter_type

The effective filter type, considering compiler version and other side conditions.

Return type:

SymbolAttributeFilterTypes

property symbol_attribute_filter_data

Describes the filter data for SymbolAttributeFilterTypes.Prefix and SymbolAttributeFilterTypes.Regex.

Return type:

str

property symbol_comment_filter_type

The configured comment filter type.

Return type:

SymbolCommentFilterType

property effective_symbol_comment_filter_type

The effective comment filter type, considering compiler version and other side conditions.

Return type:

SymbolCommentFilterType

get_all_signatures(compile=True)

Get all signatures (compiler and configured).

Parameters:

compile (bool) – If True, build the application before generating the list. If the application was not built before, the returned list is empty.

Return type:

ScriptSymbolConfigSignatureCollection

Returns:

Collection of signatures.

get_all_datatypes(compile=True)

Get all data types (compiler and configured).

Parameters:

compile (bool) – If True, build the application before generating the list. If the application was not built before, the returned list is empty.

Return type:

ScriptSymbolConfigSignatureCollection

Returns:

Collection of data types.

get_only_configured_signatures()

Get only the configured signatures.

Return type:

ScriptSymbolConfigSignatureCollection

Returns:

Collection of signatures.

get_only_configured_datatypes()

Get only the configured data types.

Return type:

ScriptSymbolConfigSignatureCollection

Returns:

Collection of data types.

class ScriptSymbolConfigObject.ScriptClientSideLayoutCalculatorDescriptionCollection(iterable=(), /)

Bases: list

Descriptions of the client side layout calculators.

Version added:

3.5.10.0

class ScriptSymbolConfigObject.ScriptClientSideLayoutCalculatorDescription

Bases: object

Description of an client side layout calculator.

Currently, two different values are allowed: Guid.Empty to use the Compatibility Offset Calculator which is always available. And “{0141eb75-141b-4ea1-9a8c-75f952b22a6c}” to use the OptimizedOutputOffsetCalculator which is new with V3.5.7.0 and also requires the compiler version 3.5.7.0 (see http://jira.3s-software.com/browse/CDS-41816). This scheme may be extended to allow more or even arbitrary offset calculators in the future.

Version added:

3.5.10.0

property type_guid

The unique ID of the output layout calculator.

Return type:

Guid

property name

The name of the output layout calculator - human readable and localized.

Return type:

str

property description

A longer description of the output layout calculator.

Return type:

This may be shown in a tooltip, and should give some detailed explanation of the calculator, and e. G. the conditions under which the calculator is valid.

class ScriptSymbolConfigObject.ScriptSymbolConfigSignature

Bases: object

Signature element of the symbol configuration.

Version added:

3.5.10.0

property name

The name of this element.

Return type:

str

property full_qualified_name

The full qualified name of this element.

Return type:

str

property library_id

The identification of the library where this signature is declared.

Return type:

str

property namespace_path

Namespace path of the library where this signature is declared.

Return type:

list <str>

property variables

The variables of the signature.

Return type:

ScriptSymbolConfigVariableCollection

class ScriptSymbolConfigObject.ScriptSymbolConfigSignatureCollection(iterable=(), /)

Bases: list

Collection of symbol configuration signatures.

Version added:

3.5.10.0

find(name, library_id=None)

Get the first ScriptSymbolConfigSignature with the specified name and library ID which should be fully qualified.

Parameters:
  • name (str) – Name of a signature.

  • library_id (str) – Library ID.

Return type:

ScriptSymbolConfigSignature

Returns:

Signature of the symbol configuration. Otherwise None.

class ScriptSymbolConfigObject.ScriptSymbolConfigVariable

Bases: object

Variable element of the symbol configuration.

Version added:

3.5.10.0

property name

The name of this variable.

Return type:

str

property type

The type of this variable, as the user declared it.

Return type:

str

property comment

Gets the comment of the signature or variable, or an empty string if no comment is available.

This member is only valid for objects parsed from the compiler, not for configured symbol config instances.

Return type:

str

property configured_access

The allowed symbolic access to this variable.

Return type:

SymbolAccess

property maximal_access

The maximal access that is allowed for this variable, decided by the given attributes.

Return type:

SymbolAccess

property effective_access

The effective symbolic access to this variable.

Return type:

SymbolAccess

property exported_via_attribute

Gets a value indicating whether this variable is configured via compiler attribute.

Return type:

bool

Returns:

True if exported via attribute; otherwise False. If True, the Access attribute gives the effective access for this variable.

property attribute_access

Gets the attribute access. When attribute_access is false, the result of this member is undefined.

Return type:

SymbolAccess

property type_library_id

Gets the library id, when the type of the member is from a library.

This is currently only set for supported data types (userdef and array).

Return type:

str

property full_qualified_base_type

Gets the full qualified base type of the member.

This is currently only set for supported data types (userdef and array).

Return type:

str

property alias_type

The name of the alias type.

For variables with aliased types, the Type, SymbolConfigVariable.VariableType and SymbolConfigVariable2.FullQualifiedBaseType properties point to the effective, resolved type. Use this member in the UI to display the alias type used in the source. This member is only valid for objects parsed from the compiler, not for configured symbol config instances.

Return type:

str

class ScriptSymbolConfigObject.ScriptApplicationSymbolConfigExtension

Bases: object

Extension provider for ApplicationObject instances.

Version added:

3.5.10.0

create_symbol_config(export_comments_to_xml, support_opc_ua, client_side_layout_calculator)

Add the symbol configuration object to an application.

Return type:

ScriptObject

Returns:

Script object of the symbol config object.

exception ScriptSymbolConfigObject.ScriptSymbolConfigInvalidObjectException(stMessage)

Bases: Exception

Exception which is thrown when the symbol configuration object is modified externally and so the scripting objects are not valid anymore.

Version added:

3.5.10.0

__init__(stMessage)

init.