ScriptSvnUIServices

class ScriptSvnUIServices.SvnUIServices

Bases: object

Contains several UI related services. The SvnIntegration.plugin provides a system instance with the type guid 21662EFC-3501-4e14-9FC3-F158E38351B2 for this interface.

ShowLog(owner, objectId)

Opens the subversion log window.

Parameters:
  • owner (Win32Window) – The owner.

  • objectId (SvnObjectId) – The object id.

SelectRevision(owner, url)

Opens the select revision dialog.

Parameters:
  • owner (Win32Window) – The owner.

  • url (Uri) – The remote url.

Return type:

int

Returns:

The subversion revision number.

CreateSvnMessageViewReporter(stName)

Creates a SVN message view reporter.

Parameters:

stName (str) – Name of the action.

Return type:

SvnReporter

Returns:

The message view reporter.

CreateSvnCheckMessageViewReporter(stName)

Creates a SVN check message view reporter.

Parameters:

stName (str) – Name of the action.

Return type:

SvnReporter

Returns:

The message view reporter.

BrowseRepository(owner, url, revision, filterCache)

Opens the repository browser window.

Parameters:
  • owner (Win32Window) – The owner window.

  • url (Uri) – The URL.

  • revision (SvnRevision) – The revision.

  • filterCache (SvnAsynchroneousAcceptFilterCache) – The OK button is only enabled if this filter returns true for the selected URL.

Return type:

DialogResult

Returns:

DialogResult.OK if the user pressed OK.

filter disables the OK button. If the filter calls nothing, the url is not accepted with a generic error message. If you really want unfiltered URLs, pass a filter which always calls accept. Uncaught exceptions also count as Deny, with the exception message as diagnostics message.

Beware that BrowseRepository can call the acceptedUrlFilter in background threads, so if you call into the object manager or interact with the UI, you will need to use Engine.InvokeInPrimaryThread or similar means.

BrowseRepositoryFixedRevision(owner, url, revision, acceptedUrlFilter)

Opens the repository browser window, with a fixed revision.

Parameters:
  • owner (Win32Window) – The owner window.

  • url (Uri) – The URL.

  • revision (SvnRevision) – The revision (which cannot be changed).

  • acceptedUrlFilter (SvnUrlAcceptFilterArgs) – The OK button is only enabled if this filter returns true for the selected URL.

Return type:

DialogResult

Returns:

DialogResult.OK if the user pressed OK.

filter disables the OK button. If the filter calls nothing, the url is not accepted with a generic error message. If you really want unfiltered URLs, pass a filter which always calls accept. Uncaught exceptions also count as Deny, with the exception message as diagnostics message.

Beware that BrowseRepository can call the acceptedUrlFilter in background threads, so if you call into the object manager or interact with the UI, you will need to use Engine.InvokeInPrimaryThread or similar means.

SelectRevisionRanges(owner, url)

Opens the select revision dialog.

Parameters:
  • owner (Win32Window) – The owner.

  • url (Uri) – The remote url.

Return type:

str

Returns:

The selected subversion revision ranges, like: 4-7,9,11,15-19

GetDecorationIcon()

Gets the status decoration icon for the given object ID, as it would be displayed in the navigator control.

Parameters:

objectId (SvnObjectId) – the object id of the object in question. This object id must relate to the local project / working copy, we cannot get status decorations for remote objects.

Return type:

Icon

Returns:

The Icon, or None if no Icon could be found.

Compare(owner, leftObjectId, leftRevision, rightObjectId, rightRevision, showSingleSided, showMarkAsResolvedButton=False)

Opens the compare window for a specific object.

Parameters:
  • owner (Win32Window) – The owner.

  • leftObjectId (SvnObjectId) – The left object id.

  • leftRevision (SvnRevision) – The left revision.

  • rightObjectId (SvnObjectId) – The right object id.

  • rightRevision (SvnRevision) – The right revision.

  • showSingleSided (bool) – If set to True, added or removed objects are shown in a single read-only editor.

  • showMarkAsResolvedButton (bool) – If set to True the Mark as Resolved button will be visible for conflict cases.

Return type:

bool

Returns:

True if the user has closed the Dialog with OK.

CompareInView(owner, leftUrl, leftRevision, rightUrl, rightRevision, showSingleSided)

Opens the compare View for two objects of different URLs. This may hapen e. G. when an object is copied and modified in the same commit, and we need to compare it against the previous state. This feature is available since development system version 3.5.12.10.

Parameters:
  • owner (Win32Window) – The owner.

  • leftUrl (Uri) – The object Url.

  • leftRevision (SvnRevision) – The left revision.

  • rightUrl (Uri) – The object Url.

  • rightRevision (SvnRevision) – The right revision.

  • showSingleSided (bool) – If set to True, added or removed objects are shown in a single read-only editor.

ShowLogView()

Opens the subversion log View.

Parameters:

objectId (SvnObjectId) – The object id.

class ScriptSvnUIServices.SvnUrlAcceptFilterArgs

Bases: object

Arguments passed to an Url Accept filter.

property Url

Gets the URL which is to be accepted.

Return type:

Uri

property Revision

Gets the revision which is to be accepted.

Return type:

SvnRevision

Accept(stDescription)

Accepts this url, and supplies a human readable (localized) description of the current url.

Parameters:

stDescription (str) – The description.

Deny(stReason)

Denies the specified url, and supplies a human readable (localized) diagnostics message.

Parameters:

stReason (str) – The reason.

class ScriptSvnUIServices.SvnUrlAcceptFilterResult

Bases: object

Provides the result of an Url Accept filter check.

property Accepted
Return type:

bool

Returns:

True, if the Url was accepted

class ScriptSvnUIServices.SvnCheckOutControl

Bases: object

Control used for the Checkout Dialog and the Checkout Action in the test driver.

is provided via the TypeGuid 135bd384-f5fd-462a-9a21-9d735310eb70.

AcceptStateChanged()

[EventHandler]

property AcceptState
Return type:

bool

property RepositoryUrl
Return type:

Uri

property Revision
Return type:

SvnRevision

property Target
Return type:

SvnUrlTarget

property LocalProjectFilePath
Return type:

str

property LocalProjectName
Return type:

str

property AsLibrary

Gets or sets a value indicating whether the project is checked out as library.

Return type:

bool

Returns:

True if the project should be checked out as library; otherwise, False.

property OmitExternals
Return type:

bool

property RepositoryUrlControl
Return type:

SvnRepositoryUrlControl

property Control
Return type:

Control

SetAssociatedOnlineHelpTopic(keword: str = None)

Sets or resets the associated online help topic. Use this when embedding the control somewhere which is not the original checkout dialog.

Parameters:
  • topic (str) – The online help topic URL.

  • keword (str) – The online help keyword.

property AutodetectProjectType

Gets or sets a value indicating whether the project type (library or project) is automatically detected.

Return type:

bool

Returns:

True if the project type is autodetected; otherwise, False.

class ScriptSvnUIServices.SvnRepositoryUrlControl

Bases: object

Control used for repository targets (URL and Revision).

StatusUpdated(eventargs: AcceptFilterUpdateEventArgs)

[Delegate] This event is fired whenever the status is updated.

TargetChanged(eventargs: TargetChangedEventArgs)

[Delegate]

property FixRevision
Return type:

SvnRevision

property ShowBrowserButton
Return type:

bool

property IsFixRevision
Return type:

bool

property Accepted
Return type:

bool

property Url
Return type:

Uri

property Revision
Return type:

SvnRevision

property Target
Return type:

SvnUrlTarget

AcceptInputToUrlHistory()
property AcceptFilterCache
Return type:

SvnAsynchroneousAcceptFilterCache

property AcceptedTarget
Return type:

SvnUrlTarget

property Control
Return type:

Control

property AdditionallyAllowedTextValidator

Use this property to allow additional texts (e. G. test manager {expressions}) to be entered in the control. Use RawUrlText to get the raw text of the url in this case.

Return type:

AdditionallyAllowedTextValidator

property RawUrlText

Use this property to get the raw text if AdditionallyAllowedTextValidator is used.

Return type:

str

SetAssociatedOnlineHelpTopic(topic: str = None, keword: str = None)

Sets or resets the associated online help topic. Use this when embedding the control somewhere where the surrounding control does not provide any useful online help.

Parameters:
  • topic (str) – The online help topic URL.

  • keword (str) – The online help keyword.

ScriptSvnUIServices.AdditionallyAllowedTextValidator(self, stUriCandidate, bAccepted, stExplanation)
Parameters:
  • stUriCandidate (str) –

  • bAccepted (bool) –

  • stExplanation (str) –

class ScriptSvnUIServices.TargetChangedEventArgs

Bases: object

property OldUrl
Return type:

Uri

property NewUrl
Return type:

Uri

property OldRevision
Return type:

SvnRevision

property NewRevision
Return type:

SvnRevision