HMI
In this dialog, you define the page template and the module visualizations which should be embedded in the toplevel visualization.
Create toplevel tab: Creates a tab in the top level of the visualization which leads directly to the visualization of this module instance.
Hotkey: With the shortcut set here, you can switch directly to this visualization page. The default setting for the shortcut is defined in the module declaration in the std.Visu section.
Page template: A template for the visualization of the module can be selected here which is used as a background for the visualization. The drop-down list provides a selection of all visualizations which are defined in the module declaration. The first visualization in the module declaration is selected by default. If no visualization defined, then "None" is displayed.
Embed visualization: This function allows for embedding the visualization of the module instance in the next superordinate module (Next ancestor) or in any other visualization of the module instance. If it is defined in the module, then the %PAGE_VISU% placeholder can be selected. In this case, the created visualization screen generated for the module instance is embedded. Multiple entries can be defined.
For information about creating visualization screens, see: Generating Visualization Screens