MC_ReadAxisError (FB)ΒΆ
FUNCTION_BLOCK MC_ReadAxisError
This function block is designed for describing general axis errors that are not related to function blocks.
Hint
This function block is equival to MC_ReadParameter when the value AxisErrorID is given on its input ParameterNumber.
- InOut:
Scope
Name
Type
Initial
Comment
Inout
AxisReference to axis
Input
EnableBOOLFALSE
While
TRUE, the outputvalueprovides the parameter value continuously for reading out.Output
ValidBOOLFALSE
TRUE: Valid outputs are available.BusyBOOLFALSE
TRUE: Execution of the function block has not finished yet.ErrorBOOLFALSE
TRUE: Error has occurred within the function block.ErrorIDSMC_ERROR0
Error identification
AxisErrorBOOLFALSE
TRUE: Axis error has occured.AxisErrorIDDWORD0
Drive specific identification of the axis error.
SWEndSwitchActiveBOOLFALSE
TRUE: Software limits are exceeded.