IOL_EventCode_Port (ENUM)¶
TYPE IOL_EventCode_Port :
Master/Port EventCode:
- Attributes:
- qualified_only
- InOut:
- Name - Initial - Comment - No_malfunction - 16#0 - No malfunction - Process_Data_mismatch - 16#17FF - Process Data mismatch – check submodule configuration (Source: Clause 7 PROFINET Lifecycle manager) - No_Device - 16#1800 - No Device (Source: SMI_PortEvent) - Startup_parameterization_error - 16#1801 - Startup parameterization error – check parameter (Source: Clause 7 PROFINET Lifecycle manager) - Incorrect_VendorID - 16#1802 - Incorrect VendorID – Inspection Level mismatch (Source: SMI_PortEvent) - Incorrect_DeviceID - 16#1803 - Incorrect DeviceID – Inspection Level mismatch (Source: SMI_PortEvent) - Short_circuit_at_CQ - 16#1804 - Short circuit at C/Q – check wire connection (Source: SMI_PortEvent) - PHY_overtemperature - 16#1805 - PHY overtemperature – check Master temperature and load (Source: SMI_PortEvent) - Short_circuit_at_L - 16#1806 - Short circuit at L+ – check wire connection (Source: SMI_PortEvent) - Overcurrent_at_L - 16#1807 - Overcurrent at L+ – check power supply (e.g. L1+) (Source: SMI_PortEvent) - Device_Event_overflow - 16#1808 - Device Event overflow - Backup_inconsistency_memory_out_of_range - 16#1809 - Backup inconsistency – memory out of range (2048 octets) (Source: SMI_PortEvent) - Backup_inconsistency_idendity_fault - 16#180A - Backup inconsistency – idendity fault (Source: SMI_PortEvent) - Backup_inconsistency_Data_storage_unspecific_error - 16#180B - Backup inconsistency – Data storage unspecific error (Source: SMI_PortEvent) - Backup_inconsistency_upload_fault - 16#180C - Backup inconsistency – upload fault (Source: SMI_PortEvent) - Parameter_inconsistency_download_fault - 16#180D - Parameter inconsistency – download fault (Source: SMI_PortEvent) - P24_missing_or_undervoltage - 16#180E - P24 (Class B) missing or undervoltage - Short_circuit_at_P24 - 16#180F - Short circuit at P24 (Class B) – check wire connection (e.g. L2+) - Short_circuit_at_IQ - 16#1810 - Short circuit at I/Q – check wiring - Short_circuit_at_CQ_of_DO - 16#1811 - Short circuit at C/Q (if digital output) – check wiring - Overcurrent_at_IQ - 16#1812 - Overcurrent at I/Q – check load - Overcurrent_at_CQ_of_DO - 16#1813 - Overcurrent at C/Q (if digital output) – check load - Invalid_cycle_time - 16#6000 - Invalid cycle time (Source: SMI_PortEvent) - Revision_fault - 16#6001 - Revision fault – incompatible protocol version (Source: SMI_PortEvent) - ISDU_batch_failed - 16#6002 - ISDU batch failed – Parameter inconsistency? (Source: SMI_PortEvent) Notification_Port_status_changed := 16#FF26, //Notification Port status changed ‒ Use “SMI_PortStatus” service to read Port status in detail 