DM1_Write (FB)ΒΆ
FUNCTION_BLOCK DM1_Write EXTENDS CBM.ETrig IMPLEMENTS IDTCProviderList
This function block sends a DM1 messages from a given local ECU (itfSourceECU).
A DM1 message contains lamp information and currently active diagnostic trouble codes (DTC).
Following information is sent by this function block:
Lamp information for following lamps:
Malfunction Indicator Lamp(MIL)
Red Stop Lamp (RSL)
Amber Warning Lamp (AWL)
Protect Lamp
All enabled diagnostic trouble codes connected to output
itfDTCProviderList(see DTCProvider function block).
- InOut:
Scope
Name
Type
Initial
Comment
Inherited from
Input
xExecuteBOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone,xError) are present at the outputs for exactly one cycle.ETrig
Output
xDoneBOOLTRUE: Action successfully completedETrig
xBusyBOOLTRUE: Function block activeETrig
xErrorBOOLTRUE: Error occurred, function block aborts actionFALSE: No errorETrig
Input
itfSourceECUIJ1939LocalECULocal ECU which should be the sender of the diagnostic message.
MalfunctionIndicatorLampMalfunction Indicator Lamp: Lamp to indicate when there is an emission related trouble code active.
RedStopLampRed Stop Lamp: Lamp to indicate a problem that is severe enough to warrant stopping the vehicle.
AmberWarningLampAmber Warning Lamp: Lamp to indicate a problem with the vehicle system but the vehicle does not need to be stopped immediately.
ProtectLampProtect Lamp: Lamp to indicate a problem with a vehicle system that is most likely not electronic subsystem related (e.g. Coolant Temperature has exceeded its defined range.)
Output
itfDTCProviderListIDTCProviderListTHIS^
mainly for graphical programming: output for connection to DTC provider function blocks
eErrordetailed error information if xError is TRUE.