TransmissionTrigger (FB)ΒΆ
FUNCTION_BLOCK TransmissionTrigger EXTENDS CBM.ETrig
This function block triggers the transmission of a parameter group.
Note
The transmission is not done immediately. The function block only sets a flag in communication stack which causes a transmission in next bus cycle.
- InOut:
Scope
Name
Type
Comment
Inherited from
Input
xExecuteBOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone,xError) are present at the outputs for exactly one cycle.ETrig
Output
xDoneBOOLTRUE: Action successfully completedETrig
xBusyBOOLTRUE: Function block activeETrig
xErrorBOOLTRUE: Error occurred, function block aborts actionFALSE: No errorETrig
Input
itfParameterGroupITransmitParameterGroupparameter group which should be transmitted.
Output
eErrordetailed error information if
xErrorisTRUE.