ReceiveWatchdog (FB)ΒΆ
FUNCTION_BLOCK ReceiveWatchdog EXTENDS CBM.LTrig
This function block monitors the reception of a specific parameter group (itfParameterGroup).
xError becomes TRUE if there is no reception after tTimeout else function block stays in busy state.
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xEnable- BOOL- TRUE: Action starts- FALSE: Action stops, outputs- xDone,- xBusy,- xErrorare resetted- LTrig - Output - xDone- BOOL- TRUE: Action successfully completed- LTrig - xBusy- BOOL- TRUE: Function block active- LTrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- LTrig - Input - itfParameterGroup- IReceiveParameterGroup- parameter group to be monitored - tTimeout- TIME- monitoring time: t#0ms = infinite timeout (no timeout monitoring) - Output - eError- detailed error information if - xErroris- TRUE.- xReceived- BOOL- TRUE: parameter group was received in previous cycle.