TraceMgrRecordUpdate2 (FUN)¶
FUNCTION TraceMgrRecordUpdate2 : RTS_IEC_RESULT
Stores entries in the ring buffer of a trace record.
This function can be used to provide the data for so called system parameters from the IEC application. (See TRACE_VAR_ADDRESS_FLAGS_SYSTEM.) If only a single entry is to be added, consider using TraceMgrRecordUpdate3 instead.
- InOut:
Scope
Name
Type
Comment
Return
TraceMgrRecordUpdate2RTS_IEC_RESULT- Returns the runtime system error code (see CmpErrors.library):
ERR_PARAMETER if hPacket or hPrevRecord is not a valid handle
ERR_NOTINITIALIZED if the packet is not currently recording (not started, trigger reached, …)
ERR_PENDING if no value is recorded for this cycle due to TracePacketConfiguration.ulEveryNCycles
ERR_FAILED if ulLen is not a multiple of the entry size (size of a time stamp plus a sample value)
Input
hPacketRTS_IEC_HANDLEThe trace packet handle
hRecordRTS_IEC_HANDLEThe trace record handle
Inout
pBufferA pointer to the buffer of trace entries
Input
ulLenUDINTThe number of bytes to copy from pBuffer