TRACE_PACKET_FLAGS (GVL)ΒΆ
Trace packet flags
- InOut:
Scope
Name
Type
Initial
Comment
Constant
TRACE_PACKET_FLAGS_NOT_INITIALIZED
UDINT16#0
The trace packet is not initialized
TRACE_PACKET_FLAGS_COMPLETED
UDINT16#1
The trace packet is complete (all records have been added)
TRACE_PACKET_FLAGS_AUTOSTART
UDINT16#2
Persistent storage of the trace and automatic start of the trace after reboot or to restore only on request
TRACE_PACKET_FLAGS_CONDITION
UDINT16#4
Optional boolean condition for the trace packet is specified
TRACE_PACKET_FLAGS_TIMESTAMP_MS
UDINT16#10
Time stamps for the trace samples have milliseond resolution
TRACE_PACKET_FLAGS_TIMESTAMP_US
UDINT16#20
Time stamps for the trace samples have microseond resolution
TRACE_PACKET_FLAGS_SYSTEM_TRACE
UDINT16#10000
Is used to mark a trace as system trace