IEC_BACNET_AUTHENTICATION_POLICY (STRUCT)ΒΆ
TYPE IEC_BACNET_AUTHENTICATION_POLICY : STRUCT
Definition of the BACnetAuthenticationPolicy structure
This structuee specifies the authentication policies defined for an Access Point object.
- InOut:
Name
Type
Comment
nPolicyCountCount of entries in the List_Of_Policies
policiesPOINTER TO IEC_BACNET_AUTHENTICATION_POLICY_DATAINPUT
This field is a list of sequence elements that specifies the Credential Data Input objects which are used for this authentication policy
fOrderEnforcedIf TRUE, then the ordering sequence, as specified by the Index fields of this Policy list, is enforced. If FALSE, then the order is not enforced.
nTimeoutThis field, of type Unsigned, specifies the maximum time in seconds for which all authentication factors, as defined by this policy, must be presented. A value of zero indicates an unlimited time to present all authentication factors. If not all authentication factors are presented in the allotted time, then a timeout occurs and authentication fails.