CODESYS GmbH
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
Menu
Search
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
  • BuildingAutomation
    • Doc
      • Aggregate variants
        • CFC-specific considerations
        • Example
      • Air types - Terms, abbreviations, and colors
      • Compile options
      • Levels of application development and functional aspects covered currently
        • Levels of application development covered currently
        • Functional aspects covered currently
      • Examples
      • Functional aspects in the building automation field
      • Implementation
        • Implementation language
        • Implementation rules
      • Introduction
      • Legal
        • Disclaimer
        • License Terms
      • Levels of building automation application development
      • Other useful resources
        • OSCAT http://www.oscat.de/
        • OSCAT BUILDING LIBRARY - computation of physics. The following are especially worth mentioning:
        • OSCAT BUILDING LIBRARY - blind modules:
      • Persistence as an option
      • System requirements and restrictions
        • Exceptions
      • System schemes
      • Visualization
      • Non-real-time testing and simulation - how to use the “warp clock”
        • What is the “warp clock”?
        • How to use the “warp clock”?
    • Enums
      • AutoOnOff (Enum)
      • EnergyLevel (Enum)
      • Error (Enum)
      • HeatCoolOperationMode (Enum)
      • ServiceIndication (Enum)
    • Function Blocks
      • Actuator
        • Fan3Stage (FunctionBlock)
        • Fan3StageState (Enum)
        • HVAC_Coil (FunctionBlock)
        • HVAC_RotaryHeatExchanger (FunctionBlock)
        • HeatCool2Linear (FunctionBlock)
        • IActuatorContinuous (Interface)
        • IActuatorOnOff (Interface)
        • IValveContinuous (Interface)
        • PumpOnOff (FunctionBlock)
        • ValveContinuous (FunctionBlock)
        • ValveSixWay (FunctionBlock)
        • ValveThermo (FunctionBlock)
        • ValveThermoWarmupState (Enum)
        • WindowActuator (FunctionBlock)
        • WindowActuatorState (Enum)
      • Aggregates
        • Examples
        • Fancoil3Stage (FunctionBlock)
        • FancoilContinuous (FunctionBlock)
      • Assemblies
        • FourToTwoPipes (FunctionBlock)
      • Control
        • CommandExecutionMonitoring (FunctionBlock)
        • CommandVariable (FunctionBlock)
        • HVAC_AntiFreezeControlMonitor (FunctionBlock)
        • HVAC_AntiFreezeControlSensor (FunctionBlock)
        • HVAC_AntiFreezeControlStartup (FunctionBlock)
        • RedundantPlantControl8 (FunctionBlock)
        • SequenceControl (FB)
        • Integrator dynamics
        • Reset
        • “Anti windup” (integration limit)
        • “Soft set”
        • SequenceControlSequences (Enum)
        • SequenceSwitch (FunctionBlock)
      • Examples
        • ExampleAirConditioning1 (FB)
        • Air types
        • ExampleAirConditioning2 (FB)
        • Air types
        • ExampleHeating (FunctionBlock)
        • ExampleHotWater (FunctionBlock)
        • ExampleRoomAutomation (FB)
        • Air types
        • ExampleVariantsRoomControlFCUSimple (FunctionBlock)
        • Examples_ImagePool (ImagePool)
      • Misc
        • DailyMeanTemperature (FunctionBlock)
        • HeatingCharacteristicCurve (FunctionBlock)
        • HysteresisReal (FunctionBlock)
        • LogBoolChange (FunctionBlock)
        • RoomSetpoint (FunctionBlock)
      • Optimization
        • EnergyLevelSetpoint (FunctionBlock)
        • HeatCoolUsingOutdoorAir (FB)
        • Cooling mode
        • Heating mode
      • Time related
        • DateTimeSplit (FunctionBlock)
        • MaxOnTime (FunctionBlock)
        • MinOnOffTime (FunctionBlock)
        • OnOffDelay (FunctionBlock)
        • OperationalTime (FunctionBlock)
        • PeriodicTimer (FunctionBlock)
        • WarpClock (FunctionBlock)
    • Functions
      • LinTransf (Function)
      • LinTransfClip (Function)
      • LinTransfNormalized (Function)
      • Log
      • RealEquals (Function)
      • RealGreaterEqual (Function)
      • RealInRange (Function)
      • RealLessEqual (Function)
      • ServiceIndicationValue (Function)
      • Time related
        • DateTimeToString (Function)
      • UdintInRange (Function)
  • GlobalTextList (GlobalTextList)
  • TextListForCombobox_AutoOnOff (TextList)
  • TextListForCombobox_EnergyLevel (TextList)
  • TextListForCombobox_Error (TextList)
  • TextListForCombobox_Fan3StageState (TextList)
  • TextListForCombobox_HeatCoolOperationMode (TextList)
  • TextListForCombobox_SequenceControlSequences (TextList)
  • TextListForCombobox_ValveThermoWarmupState (TextList)
  • TextListForCombobox_WEEKDAY (TextList)
  • TextListForCombobox_WindowActuatorState (TextList)
  • File and Project Information
  • Library Reference
    • CmpBitmapPool
      • Library Identification
      • Library Properties
    • CmpErrors2 Interfaces
      • Library Identification
      • Library Properties
    • CmpLog
      • Library Identification
      • Library Properties
    • Common Behaviour Model
      • Library Identification
      • Library Properties
    • Component Manager
      • Library Identification
      • Library Properties
    • Standard
      • Library Identification
      • Library Properties
    • SysTimeRtc
      • Library Identification
      • Library Properties
    • SysTypes Interfaces
      • Library Identification
      • Library Properties
    • Util
      • Library Identification
      • Library Properties
      • Library Parameter
    • VisuElem3DPath
      • Library Identification
      • Library Properties
      • Library Parameter
    • VisuElemCamDisplayer
      • Library Identification
      • Library Properties
      • Library Parameter
    • VisuElemMeter
      • Library Identification
      • Library Properties
    • VisuElemTextEditor
      • Library Identification
      • Library Properties
    • VisuElemTrace
      • Library Identification
      • Library Properties
    • VisuElemXYChart
      • Library Identification
      • Library Properties
    • VisuElems
      • Library Identification
      • Library Properties
    • VisuElemsAlarm
      • Library Identification
      • Library Properties
    • VisuElemsDateTime
      • Library Identification
      • Library Properties
    • VisuElemsSpecialControls
      • Library Identification
      • Library Properties
    • VisuElemsWinControls
      • Library Identification
      • Library Properties
    • VisuInputs
      • Library Identification
      • Library Properties
    • VisuNativeControl
      • Library Identification
      • Library Properties
    • VisuSymbols
      • Library Identification
      • Library Properties
Building Automation
  • Docs »
  • BuildingAutomation »
  • Function Blocks »
  • Aggregates

Aggregates¶

Function blocks for building automation specific aggregates are collected in this folder.

  • Examples
    • ExampleFancoil3StageAggregate (FunctionBlock)
  • Fancoil3Stage (FunctionBlock)
    • Functionality
    • Control of fan speed dependent on valve position or control deviation
  • FancoilContinuous (FunctionBlock)
    • Application example
    • Device examples
    • Why does CODESYS Building Automation library contain a fan coil unit control strategy, even if some fan coil units come with integrated controller?
    • Functionality
    • Characteristic curve of fan speed
top

CODESYS Group | We software Automation. to software
['sɒftwɛər]
transitive verb
__softwared/softwaring
: to develop software
// to software automation: to develop software for automation purposes

The CODESYS Group is the manufacturer of CODESYS, the leading hardware-independent IEC 61131-3 automation software for developing and engineering controller applications.
CODESYS® is a registered trademark.

CODESYS GmbH
A member of the CODESYS Group
Memminger Straße 151, 87439 Kempten
Germany
Tel.: +49-831-54031-0
info@codesys.com
  • Legal Notice
  • Privacy Policy
LinkedIn Youtube RSS Downloads Login CODESYS Store
© 2022 CODESYS GmbH | A member of the CODESYS Group