Visualization Element: Meter 180°
Symbol:

Category: Measurement Controls
The element displays the value of a variable. The needle is positioned according to the value of the assigned variable on a scale. A meter is used to represent a tachometer, for example.
Element properties
Are all element properties available?
All properties are available only after you select the Advanced option or the All categories filter in Properties.
Element name | Example: Name assignmentAssign individual names for elements so that they are found faster in the element list. |
Element Type | Meter 180° |
Value | Variable (numeric data type) The variable value determines the pointer direction of the element. |
Center
The properties contain fixed values for the coordinates of the point of rotation. The rotation point is displayed in the editor as the
symbol and is used as the center for rotation and scaling.
Tip
You can also change the values by dragging the
symbol to another position in the editor.
X | Editable X-coordinate of the point of rotation Double-clicking in the value field will open the line editor. |
Y | Editable Y-coordinate of the point of rotation Double-clicking in the value field will open the line editor. |
Absolute movement
The properties contain IEC variables for controlling the position of the element dynamically. The reference point is the upper left corner of the element. At runtime, the entire element is moved.
Movement | ||
X |
Increasing this value at runtime moves the element to the right. | |
Y |
Increasing this value at runtime moves the element downwards. | |
Rotation | Variable (numeric data type) for the angle of rotation (in degrees) Example: The midpoint of the element rotates at the Center point. This rotation point is shown as the At runtime, the alignment of the element remains the same with respect to the coordinate system of the visualization. Increasing the value rotates the element to the right. | ![]() |
Scaling | Variable (integer data type) to trigger a centric stretching Example: The reference point is the Center property. The value | |
Interior rotation | Variable (numeric data type) for the angle of rotation (in degrees) Example: At runtime, the element rotates about the point of rotation specified in Center according to the value of the variable. In addition, the alignment of the element rotates according to the coordinate system of the visualization. Increasing the value in the code rotates clockwise. The rotation point is shown as the NoteIf a static angle of rotation is specified in the property, then the static angle of rotation is added to the variable angle of rotation (offset) when the visualization is executed. | ![]() |
Tip
You can combine the variables to a Unit conversion.
Tip
The X, Y, Rotation, and Interior rotation properties are supported by the "Client Animation" functionality.
Animation
Tip
These properties are available only when you have selected the Support client animations and overlay of native elements option in the Visualization Manager.
Animation duration | Variable for the duration (in milliseconds) in which the element runs an animation
. Animatable properties
The animated movement is executed when at least one value of an animatable property has changed. The movement then executed is not jerky, but is smooth within the specified animation duration. The visualization element travels to the specified position while rotating dynamically. The transitions are smooth. |
Move to foreground | Variable (
Example: |
Position
The position defines the location and size of the element in the visualization window. This is based on the Cartesian coordinate system. The origin is located in the upper left corner of the window. The positive horizontal X-axis runs to the right. The positive vertical Y-axis runs downwards.
X | The X-coordinate (in pixels) of the upper left corner of the element Example: |
Y | The Y-coordinate (in pixels) of the upper left corner of the element Example: |
Width | Specified in pixels Example: |
Height | Specified in pixels Example: |
Tip
You can change the values by dragging the box
symbols to other positions in the editor.
Background
Image color | List box containing background colors |
Own image |
|
Pointer
Arrow type | List box with different arrow types |
Color |
|
Angle range | List box for the alignment of the element |
Additional arrow |
|
Scale
Sub scale position |
|
Scale type | Possible scale types:
|
Scale start | Least value of the scale and the lower limit of the value range for the element Example: TipIn the value field, click the |
Variable | Variable (integer data type) for the start value of the scale Example: |
Scale end | Greatest value of the scale and the upper limit of the value range for the element Example: 100 TipIn the value field, click the |
Variable | Variable (integer data type) for the scale end Example: |
Main scale | Distance between two values on the main scale Example: TipIn the value field, click the |
Variable | Variable (integer data type) Contains the distance. Example: |
Sub scale | Distance between two values on the fine scale Example: TipYou can hide the fine scale by setting the value to TipIn the value field, click the |
Variable | Variable (integer data type) for the spacing between two values on the fine scale Example: |
Scale line width | In pixels Example: 3 |
Scale color | Color of the tick marks
|
Scale in 3D |
NoteThis property is not displayed in FlatStyle style. |
Show scale |
|
Frame inside |
|
Frame outside |
|
Note
A valid declaration in the application code is required for the variables used as an example in the table above.
Label
Label |
|
Unit | Text which is displayed in the element Example: Display of unit in m/s |
Font | Font for labels (example: scale numbering). Selection from the list box or by clicking the |
Scale format (C syntax) | Values scaled in Examples: |
Max. text width of labels | Optional value that defines the maximum width of the scale label The value is set automatically. TipChange this value only if the automatic adjustment does not yield the expected result. |
Text height of labels | Optional value that defines the maximum height of the scale label The value is set automatically. TipChange this value only if the automatic adjustment does not yield the expected result. |
Font color | Selection from the list box or by clicking the |
Positioning
Usage of | Preset style values: Values from the current style User-defined settings: The subnode Positioning appears. |
Positioning | Requirement: User-defined settings is selected as Usage of. The displayed positioning settings depend on the type of needle instrument and potentiometer, and partially on whether a custom background image is selected. The following settings are used for achieving the exact position relative to the background image. |
Needle movement | Length of the needle (in pixels) |
Scale movement | Requirement: A customer image is selected as Background. Distance from the tick marks to the center (in pixels) |
Scale length | Requirement: A customer image is selected as Background. Length of the tick marks (in pixels) |
Label offset: | Distance from the labels to the tick marks (in pixels) |
Unit offset: | Distance of the unit text from the upper scale edge (in pixels) |
Origin offset | Requirement: For the elements Meter 180° and Meter 90°, this property is displayed only if a custom image is selected as Background. Offset of the element (in pixels) |
Colors
Color areas | |
Durable color areas |
|
Use colors for scale |
|
Color areas | |
Create new | Adds a new color range in the Elements view |
Delete | Removes from the list the color range and refreshes the list |
Begin of area | Start value of the color area Example: 20 TipThe Variable property is displayed below the |
Variable | Variable (integer data type) for the start of the area Example: Declaration: PROGRAM PLC_PRG
VAR
iColorAreaStart0 : INT := 80;
END_VAR |
End of area | End value of the color area Example: 120 TipThe Variable property is displayed below the |
Variable | Variable (integer data type) for the end of the area Example: Declaration: PROGRAM PLC_PRG
VAR
iColorAreaEnd0: INT := 100;
END_VAR |
Color | Color that is used for displaying the area |
State variables
The variables control the element behavior dynamically.
Invisible | Variable (
|
Tip
The Invisible property is supported by the "Client Animation" functionality.
Permissions
Note
Available only when a user management is set up for visualization.
Access Rights button | Opens the Access Rights dialog. There you can edit the access privileges for the element. . Status messages:
|






