Visualization Element: Lamp

Symbol:

_visu_img_lamp.png

Category: Lamps/Switches/Bitmaps

The element shows the value of a variable, and the element is displayed as illuminated or not.

Element properties

Are all element properties available?

All properties are available only after you select the Advanced option or the All categories filter in Properties.

Element name

Example: Lamp_green

Name assignment

Assign individual names for elements so that they are found faster in the element list.

Element Type

Lamp

Position

The position defines the location and size of the element in the visualization window. This is based on the Cartesian coordinate system. The origin is located in the upper left corner of the window. The positive horizontal X-axis runs to the right. The positive vertical Y-axis runs downwards.

X

The X-coordinate (in pixels) of the upper left corner of the element

Example: 10

Y

The Y-coordinate (in pixels) of the upper left corner of the element

Example: 10

Width

Specified in pixels

Example: 150

Height

Specified in pixels

Example: 30

Tip

You can change the values by dragging the box _visu_icon_position_element.png symbols to other positions in the editor.

Variable

Variable

Variable (BOOL).

The variable value is displayed as a lamp that goes on (TRUE) or off (FALSE).

Image Settings

Transparency

standard icon: The Transparent color property is selected.

Transparent color

Requirement: Transparency is activated.

All pixels of the specified color are displayed as transparent.

_cds_icon_three_dots.png: The Color color picker dialog opens

_cds_icon_arrow_down.png: The list box with style properties opens.

Scaling type

Reaction of the element when the dimension of the Frame element is changed:

  • Isotropic: The height and width of the image are resized proportionally to the Frame.

    Note: To retain the alignment of elements also within a scaled Frame element, define the Horizontal alignment or Vertical alignment explicitly with Centered.

  • Anisotropic: The image fills the entire Frame regardless of its proportions.

Horizontal alignment

Requirement: The Scaling type is Isotropic.

Horizontal alignment of the image within the element frame or element

  • Left

  • Centered

  • Right

Vertical alignment

Requirement: The Scaling type is Isotropic.

Vertical alignment of the image within the element frame or element:

  • Top

  • Centered

  • Bottom

Texts

Tooltip

String (without single straight quotation marks)

Example: Products of customer A

The text is output as a tooltip. If a placeholder %<format string> is specified in the text, then the value of the variable in the Text variable → Tooltip property is output at the location of the placeholder.

Tip

Use the Ctrl + Enter shortcut to add a line break.

Tip

The specified texts are automatically transferred to the GlobalTextList text list. Therefore, these texts can be localized.

State variables

The variables control the element behavior dynamically.

Invisible

Variable (BOOL) for toggling the visibility of the element

TRUE: The element is not visible at runtime.

Tip

The Invisible property is supported by the "Client Animation" functionality.

Center

The properties contain fixed values for the coordinates of the point of rotation. The rotation point is displayed in the editor as the _visu_icon_center_point.png symbol and is used as the center for rotation and scaling.

Tip

You can also change the values by dragging the _visu_icon_center_point.png symbol to another position in the editor.

X

Editable X-coordinate of the point of rotation

Double-clicking in the value field will open the line editor.

Y

Editable Y-coordinate of the point of rotation

Double-clicking in the value field will open the line editor.

Absolute movement

The properties can be assigned to IEC variables for controlling the position of the element dynamically. The reference point is the upper left corner of the element. At runtime, the entire element is moved.

Movement

X

  • Variable (numeric data type) for the X-position (in pixels)

    Example: PLC_PRG.iPos_X

Increasing this value at runtime moves the element to the right.

Y

Increasing this value at runtime moves the element downwards.

Rotation

Variable (numeric data type) for the angle of rotation (in degrees)

Example: PLC_PRG.iAngle1

The midpoint of the element rotates at the Center point. This rotation point is shown as the _visu_icon_center_point.png symbol.

At runtime, the alignment of the element remains the same with respect to the coordinate system of the visualization. Increasing the value rotates the element to the right.

_visu_img_prp_rotation.png

Interior rotation

Variable (numeric data type) for the angle of rotation (in degrees)

Example: PLC_PRG.iAngle2

At runtime, the element rotates about the point of rotation specified in Center according to the value of the variable. In addition, the alignment of the element rotates according to the coordinate system of the visualization. Increasing the value in the code rotates clockwise.

The rotation point is shown as the _visu_icon_center_point.png symbol.

Note

If a static angle of rotation is specified in the Position → Angle property, then the static angle of rotation is added to the variable angle of rotation (offset) when the visualization is executed.

_visu_img_prp_inner_rotation.png

Tip

You can combine the variables to a Unit conversion.

Tip

The X, Y, Rotation, and Interior rotation properties are supported by the "Client Animation" functionality.

Animation

Tip

These properties are available only when you have selected the Support client animations and overlay of native elements option in the Visualization Manager.

Animation duration

Variable for the duration (in milliseconds) in which the element runs an animation

  • Variable (integer value)

    Example: Menu.tContent with VAR tContent : INT := 500; END_VAR

  • Integer literal

    Example: 500

. Animatable properties
  • Absolute movement, Movement, X, Y

  • Absolute movement, Rotation

  • Absolute movement, Interior rotation

  • Absolute movement, Exterior rotation

The animated movement is executed when at least one value of an animatable property has changed. The movement then executed is not jerky, but is smooth within the specified animation duration. The visualization element travels to the specified position while rotating dynamically. The transitions are smooth.

Move to foreground

Variable (BOOL) for setting the element in the foreground

TRUE: At runtime, the visualization element is displayed in the foreground.

FALSE: At runtime, the visualization element is displayed in the layer where it was inserted in the visualization editor.

Example: bIsInForeground with VAR bIsInForeground : BOOL := FALSE; END_VAR

Background

Image

List box containing background colors

Note

The color names have been defined in the visualization style and vary according to the selected visualization style.

Permissions

Note

Available only when a user management is set up for visualization.

Access Rights button

Opens the Access Rights dialog. There you can edit the access privileges for the element.

. Status messages:
  • Not set. Full rights.: Access rights for all user groups : operable

  • Rights are set: Limited rights: Access is restricted for at least one group.