Skip to main content

Visualization Element: Check Box

Symbol:

_visu_img_button.png

Category: Common Controls

The check box can have the states enabled (1) and disabled (0). When enabled, the box has a check mark.

Element properties

Are all element properties available?

All properties are available only after you select the Advanced option or the All categories filter in Properties.

Element name

Example: Voltage_on

Name assignment

Assign individual names for elements so that they are found faster in the element list.

Element Type

Button

Variable

Variable (BOOL)

Example: PLC_PRG.xIsTRUE

Frame size

Distance of the element to the edge

Example: From style

Position

The position defines the location and size of the element in the visualization window. This is based on the Cartesian coordinate system. The origin is located in the upper left corner of the window. The positive horizontal X-axis runs to the right. The positive vertical Y-axis runs downwards.

X

The X-coordinate (in pixels) of the upper left corner of the element

Example: 10

Y

The Y-coordinate (in pixels) of the upper left corner of the element

Example: 10

Width

Specified in pixels

Example: 150

Height

Specified in pixels

Example: 30

Tip

You can change the values by dragging the box _visu_icon_position_element.png symbols to other positions in the editor.

Texts

Text

String (without single straight quotation marks)

Example: Accesses: %i

The element is labeled with this text. If a placeholder %<format string> is specified in the text, then the value of the variable in the Text variable → Text property is output at the location of the placeholder.

Tooltip

String (without single straight quotation marks)

Example: Number of valid accesses %n

The text is output as a tooltip. If a placeholder %<format string> is specified in the text, then the value of the variable in the Text variable → Tooltip property is output at the location of the placeholder.

Tip

Use the Ctrl + Enter shortcut to add a line break.

Tip

The specified texts are automatically transferred to the GlobalTextList text list. Therefore, these texts can be localized.

Text properties

The properties get fixed values for the text properties and act on the texts configured in Texts → Text or Texts → Tooltip.

Horizontal alignment

Horizontal alignment of the text within the element

Vertical alignment

Vertical alignment of the text within the element

Text format

. Definition for displaying texts that are too long
  • Default: The text which is too long is truncated.

  • Line break: The text is split into lines.

  • Ellipsis: The visible text ends with "..." indicating that it is not complete.

Font

Example: Default

_cds_icon_three_dots.png: The Font dialog opens.

_cds_icon_arrow_down.png: List box with style fonts

Font color

Example: Black

_cds_icon_three_dots.png: The Color dialog opens.

_cds_icon_arrow_down.png: List box with style colors

Transparency

Integer (value range from 0 to 255)

The transparent value determines the transparency of the respective color.

255: The color is opaque.

0: The color is completely transparent.

Read-only transparency

The property is read-only when the color is a style color with a predefined transparency value.

State variables

The variables control the element behavior dynamically.

Invisible

Variable (BOOL) for toggling the visibility of the element

TRUE: The element is not visible at runtime.

Example: bIsVisible with VAR bIsVisible : BOOL := FALSE; END_VAR

Deactivate inputs

Variable (BOOL) for toggling the operability of the element

TRUE: User inputs do not have any effect in runtime more. The element is shown as deactivated.

Tip

The Invisible property is supported by the "Client Animation" functionality.

Center

The properties contain fixed values for the coordinates of the point of rotation. The rotation point is displayed in the editor as the _visu_icon_center_point.png symbol and is used as the center for rotation and scaling.

Tip

You can also change the values by dragging the _visu_icon_center_point.png symbol to another position in the editor.

X

Editable X-coordinate of the point of rotation

Double-clicking in the value field will open the line editor.

Y

Editable Y-coordinate of the point of rotation

Double-clicking in the value field will open the line editor.

Absolute movement

The properties contain IEC variables for controlling the position of the element dynamically. The reference point is the upper left corner of the element. At runtime, the entire element is moved.

Movement

X

  • Variable (numeric data type) for the X-position (in pixels)

    Example: PLC_PRG.iPos_X.

Increasing this value at runtime moves the element to the right.

Y

Increasing this value at runtime moves the element downwards.

Rotation

Variable (numeric data type) for the angle of rotation (in degrees)

Example: PLC_PRG.iAngle1.

The midpoint of the element rotates at the Center point. This rotation point is shown as the _visu_icon_center_point.png symbol.

At runtime, the alignment of the element remains the same with respect to the coordinate system of the visualization. Increasing the value rotates the element to the right.

_visu_img_prp_rotation.png

Scaling

Variable (integer data type) to trigger a centric stretching

Example: PLC_PRG.iScaling.

The reference point is the Center property.

The value 1 shrinks the element by a factor of 0.001. The value 1000 returns the element to its original size.

Tip

You can combine the variables to a Unit conversion.

Tip

The X, Y, Rotation, and Interior rotation properties are supported by the "Client Animation" functionality.

Animation

Tip

These properties are available only when you have selected the Support client animations and overlay of native elements option in the Visualization Manager.

Animation duration

Variable for the duration (in milliseconds) in which the element runs an animation

  • Variable (integer value)

    Example: Menu.tContent with VAR tContent : INT := 500; END_VAR

  • Integer literal

    Example: 500

. Animatable properties
  • Absolute movement, Movement, X, Y

  • Absolute movement, Rotation

  • Absolute movement, Interior rotation

  • Absolute movement, Exterior rotation

The animated movement is executed when at least one value of an animatable property has changed. The movement then executed is not jerky, but is smooth within the specified animation duration. The visualization element travels to the specified position while rotating dynamically. The transitions are smooth.

Move to foreground

Variable (BOOL) for setting the element in the foreground

TRUE: At runtime, the visualization element is displayed in the foreground.

FALSE: At runtime, the visualization element is displayed in the layer where it was inserted in the visualization editor.

Example: bIsInForeground with VAR bIsInForeground : BOOL := FALSE; END_VAR

Input Configuration

The properties contain the configurations for the user input when using the mouse or keyboard. A user input defines an event and one or more actions that are executed when an event occurs.

Tip

The Configure button opens the Input Configuration dialog. There you can create or edit user inputs.

Configured user inputs are listed below the events. They each include the action that is triggered and the setting in short form.

Example: Execute ST Code: _visu_icon_action.png PLC_PRG.i_x := 0;

OnDialogClosed

Input event: The user closes the dialog.

OnMouseClick

Input event: The user clicks the mouse button completely in the element area. The mouse button is clicked and released.

OnMouseDown

Input event: The user clicks down on the mouse button.

OnMouseEnter

Input event: The user drags the mouse pointer to the element.

OnMouseLeave

Input event: The user drags the mouse pointer away from the element.

OnMouseMove

Input event: The user moves the mouse pointer over the element area.

OnMouseUp

. Input events:
  • The user releases the mouse button within the element area. It is irrelevant whether the user has previously pressed the mouse button inside or outside the element area.

  • The user presses the mouse button within the element area, leaves the element area, and then releases the mouse button.

Note

This CODESYS-specific triggering behavior guarantees that actions for key elements are completed. A key element starts an action for OnMouseDown and ends the action for OnMouseUp.

Example: A visualization user presses the mouse button within the element area of the key element and then moves the cursor position so that it is located outside of the element area. The action is ended anyway because OnMouseUp is triggered.

OnValueChanged

Event which triggers follow-up actions due to a change in value

Which follow-up actions are triggered is configured in the Input Configuration dialog.

The defined follow-up actions and the corresponding configuration are displayed below the element property.

The OnValueChanged event can be disabled by the VISU_NO_VALUECHANGED compiler define in the properties dialog of the application.

Tap

When a mouse click event occurs, the variable defined in Variable is described in the application. The coding depends on the Tap FALSE and Tap on enter if captured options.

Variable

Requirement: The Tap FALSE option is not activated.

Variable (BOOL) for the mouse click event

TRUE: A mouse click event exists. It lasts as long as the user presses the mouse button over the element. It ends when the button is released.

FALSE: A mouse click event does not exist.

Example: PLC_PRG.bIsTapped

Tap FALSE

standard icon: The mouse click event leads to a complementary value in Variable.

TRUE: A mouse click event does not exist.

FALSE: While the mouse click event exists.

Tap on enter if captured

standard icon: During user input, it is also taken into consideration whether the mouse pointer is dragged within the element area or not while the mouse button is pressed.

TRUE: While the mouse click event exists and the mouse pointer is moved over the element area.

FALSE: A mouse click event does not exist. Or the user moves the mouse pointer outside of the element area while the mouse button is pressed.

The value is TRUE again as soon as the user moves the pointer back to the element area. The mouse is then captured.

Switch over

With the onset of a mouse click event, the variable is set; when the mouse click event is completed, the variable is reset.

Variable

Variable (BOOL) for toggling at the end of the mouse click event

This is when the user releases the mouse button while the mouse pointer is over the element area. If the user releases the mouse button while the mouse pointer is outside of the element area, then the mouse click event is not ended and the value is not toggled.

Tip

The user can cancel a started toggle input by dragging the mouse pointer out of the element area.

Toggle on up if captured

standard icon: The value toggles regardless of where the mouse pointer is when the mouse button is released. The mouse is then captured.

Hotkey

Shortcut on the element for triggering specific input actions

When the hotkey event occurs, the input actions in the Events property are triggered. In this way, it is not the input action itself that leads to this input action, but the mouse input action.

Key

Key pressed for input action.

Example: T

The following properties appear when a key is selected.

Events

  • None

  • Mouse down: Pressing the key triggers the input actions that are configured in the OnMouseDown property.

  • Mouse up: Releasing the key triggers the input actions that are configured in the OnMouseUp property.

  • Mouse down/up: Pressing and releasing the key triggers the input actions that are configured in the OnMouseDown property and the OnMouseUp property.

Switch over

standard icon: Combination with the "Shift" key

Example: Shift+T.

Control

standard icon: Combination with the "Ctrl" key

Example: Ctrl+T.

Alt

standard icon: Combination with the "Alt" key

Example: Alt+T.

Tip

All keyboard shortcuts and their actions that are configured in the visualization are listed on the Keyboard Configuration tab.

Permissions

Note

Available only when a user management is set up for visualization.

Access Rights button

Opens the Access Rights dialog. There you can edit the access privileges for the element.

. Status messages:
  • Not set. Full rights.: Access rights for all user groups : operable

  • Rights are set: Limited rights: Access is restricted for at least one group.