Object: Logical Exchange GVL
Added below the standard application
For more information, see: Logical I/O for Data Exchange with the Standard Controller
| Indicates a changed POU. |
Logical Exchange Mapping | Logical I/O for exchange. |
Qualified Only |
|
Use combined type |
The variable with the combined data type automatically gets the name of the logical exchange GVL. |
Button: Update | Updates. ImportantIf changes are made in the connected logical exchange device, then the Update button in the logical exchange GVL must be clicked in order to update the variable list. |
Button: Reset | Resets and terminates the existing connection. |
Editor
Important
The type consistency of the variable exchange is guaranteed only if the application versions on the EtherCAT Safety Module and on the main controller correspond to the version of the same compilable project.
Only data whose variables have a standard data type can be exchanged. Variables of a data type with the SAFE prefix cannot be exchanged between a EtherCAT Safety Module and a standard controller.
A change of the variable exchange can only become active by downloading the safety application and the standard application again.
Declaration editor for data exchange
For more information, see: Declaration Editor