View: Topology Views

Function: With the view, you can display the PLCs entered on the Automation Server and their network topology in a freely selectable screen.

Call: CODESYS Automation Server → PLCs

+ New Topology View

Opens the Create Topology View dialog.

List of topology views

Info

Shows information about the selected topology view

_cas_icon_editing.png

Edit

Opens the Edit Topology View window

_cas_icon_icons.png

Icons

Opens the Manage Topology Icons dialog

In the dialog, you can select and upload an image from the file directory. Then this image is available as a custom icon when you select an icon for an element of the topology view via the Properties view.

_cas_icon_erase.png

Delete

Opens the Delete Topology View dialog for prompting whether the selected topology view should be deleted

_cas_icon_lock.png

Permissions

Opens the <topology view> Permissions dialog to grant permissions for access to the topology view

For more information, see: <object> Permissions

Table 27. Dialog: Create Topology View

Name

Name for the new topology view

Description

Optional description

Image

  • Select Image:

    Opens the default Upload File dialog for selecting a background image for the topology view

  • _cas_icon_delete_small.png: Deletes the selected background image

Create

Creates and opens the new topology view



Table 28. Edit Topology View View

Name

Name of the topology view

Editable

Description

Input field for a description of the topology view

Image

Opens the default Upload File dialog for selecting a background image for the topology view

_cas_icon_delete_small.png

Deletes the background image

Background color

_cas_icon_color_on.png: The background color can be changed. Clicking in the underlying field, which shows the currently selected background color, opens the Color dialog to select a color.

_cas_icon_color_off.png: The background color cannot be changed.

Navigation

PLC

When you drag this item to the topology view, you position a PLC in the topology view.

PLC group

When you drag this item to the topology view, you position a PLC group in the topology view.

Topology view

When you drag this item to the topology view, you position the reference to another topology view in the topology view.

_cas_icon_delete_small.png

Opens the Delete Topology View dialog for prompting whether this topology view should be deleted

Save

Saves the current topology view and opens the Topology Views window

Cancel

Cancels the editing of the topology view



Table 29. View: Properties

Requirement: The open topology view contains at least one element.

Name

Name of the selected element

Description

Input field for a description

Size

Specified as a percentage or set via the slider

Icon

Opens the Select Topology Icon dialog for selecting a default icon or a custom icon

Installed PLC

Requirement: A PLC is selected in the topology view.

The Select PLC dialog opens. In the dialog, all PLCs are listed that are registered in the server.

New tag

Requirement: A PLC group is selected in the topology view.

Input field for a tag for the PLC group

Topology view

Requirement: A topology view is selected in the topology view.

The Select Topology View dialog opens. In the dialog, select the topology view that should be referenced.



For more information, see: Creating a Topology View