Assert_ArrayOfUSInt_ContainsNoneOf (FUN)¶
FUNCTION Assert_ArrayOfUSInt_ContainsNoneOf : BOOL
Assertion function to check that an
ARRAY OF USINT contains none of the specified values.- InOut:
Scope
Name
Type
Initial
Comment
Return
Assert_ArrayOfUSInt_ContainsNoneOfBOOLTRUEif the assertion passes succesfully,FALSEotherwiseInput
contextThe instance of the test function block calling this function.This instance can be provided by usingTHIS^.referenceValuesPOINTER TO USINT
An array with all values that should not be contained.actualArrayPOINTER TO USINT
The array to check
wsErrorMsgWSTRING(Constants.WSTRING_LENGTH)“”
A custom error message, that is added to the error message of the assertion itself.If this parameter is used, it is recommended to adapt the value of the library parameter Constants.WSTRING_LENGTH.