Assert_LReal_NotEqual (FUN)¶
FUNCTION Assert_LReal_NotEqual : BOOL
Assertion function to check unequality of two values of type
LREALThe assertion passes for
(referenceValue - precision) > actualValue AND (referenceValue + precision) > actualValue- InOut:
Scope
Name
Type
Initial
Comment
Return
Assert_LReal_NotEqualBOOLTRUEif the assertion passes succesfully,FALSEotherwiseInput
contextThe instance of the test function block calling this function.This instance can be provided by usingTHIS^.referenceValueLREALThe reference value
actualValueLREALThe value to check
precisionLREAL0.0
A value to specify an allowed deviation. Default is 0.0
wsErrorMsgWSTRING(Constants.WSTRING_LENGTH)“”
A custom error message, that is added to the error message of the assertion itself.If this parameter is used, it is recommended to adapt the value of the library parameter Constants.WSTRING_LENGTH.