Assert_ArrayOfDInt_ContainsNoneOf (FUN)¶
FUNCTION Assert_ArrayOfDInt_ContainsNoneOf : BOOL
Assertion function to check that an
ARRAY OF DINT
contains none of the specified values.- InOut:
Scope
Name
Type
Initial
Comment
Return
Assert_ArrayOfDInt_ContainsNoneOf
BOOL
TRUE
if the assertion passes succesfully,FALSE
otherwiseInput
context
The instance of the test function block calling this function.This instance can be provided by usingTHIS^
.referenceValues
POINTER TO DINT
An array with all values that should not be contained.actualArray
POINTER TO DINT
The array to check
wsErrorMsg
WSTRING(Constants.WSTRING_LENGTH)
“”
A custom error message, that is added to the error message of the assertion itself.If this parameter is used, it is recommended to adapt the value of the library parameter Constants.WSTRING_LENGTH.