SncDeviceDriverBase.Initialize (METH)ΒΆ
METHOD Initialize : ERROR
- Method to initialize the corresponding device driver to a given F-SPS and to register it to the global service provicder.
If not done yet the global service provider is initialized, too. By initializing the service provider its linked SNC service handler is registered to the RTS service handler.
- Error return values:
ERROR.ERR_OK -> success
ERROR.ERR_NO_SERVICE_PROVIDER -> the given service provider is invalid (null pointer)
ERROR.ERR_START_SERVICE_PROVIDER -> the given service provider could not be started because the registering of the SNC service handler to the RTS service handler failed
ERROR.ERR_DRIVER_INVALID -> this driver is invalid for registering
ERROR.DRIVER_IS_ALREADY_REGISTERED -> this driver is already registered to the given service provider
- InOut:
Scope
Name
Type
Comment
Input
dwVendorIDDWORDvendor ID from the device description
dwFSpsAddressDWORDaddress from the device description
wMasterIdxWORDindex of first master
Return
Initialize