MC_Halt_SML (FB)¶
FUNCTION_BLOCK FINAL MC_Halt_SML
Commands a controlled motion stop.
The axis is moved to the state DiscreteMotion, until the velocity is zero.
When the output Done is set, the state is transferred to Standstill.
Note
MC_Halt_SML is used to stop the axis under normal operation conditions.
It is possible to start another motion command during deceleration of the axis,
which will abort MC_Halt_SML and will be executed immediately.
The example below shows the behavior in combination with MC_MoveVelocity_SML.
A rotating axis is ramped down with Function Block
MC_Halt_SML
Another motion command overrides the
MC_Halt_SMLcommand.MC_Halt_SMLallows this, in contrast to MC_Stop_SML.
The axis can accelerate again without reaching Standstill.
 
- InOut:
- Scope - Name - Type - Comment - Inout - Axis- Reference to the axis - Input - Execute- BOOL- Rising edeg: The halt is started - Deceleration- LREAL- Value of the deceleration (decreasing energy of the motor) [u/s²] - Output - Done- BOOL- Becomes true as soon as the axis has reached velocity zero - Busy- BOOL- TRUEas long as- MC_Halt_SMLis operating, reset when velocity is zero- CommandAborted- BOOL- Commanded motion was interrupted by any motion FB acting on the same axis - Error- BOOL- Signals that an error has occured - ErrorID- Error number 