MC_ReadStatus_SML (FB)ΒΆ

FUNCTION_BLOCK MC_ReadStatus_SML

Returns the axis state according to the PLCopen the state diagram for a given axis.

../_images/PLCopenStateDiagram1.png
InOut:

Scope

Name

Type

Comment

Inout

Axis

Axis_REF_SML

Reference to the axis

Input

Enable

BOOL

The status is updated continuously while enabled

Output

Valid

BOOL

The status is valid

Busy

BOOL

The FB is not finished and new output values are to be expected

Error

BOOL

An error has occurred

ErrorID

SML_ERROR

The error number

ErrorStop

BOOL

The axis is in state ErrorStop

Disabled

BOOL

The axis is in state Disabled

Stopping

BOOL

The axis is in state Stopping

Homing

BOOL

The axis is in state Homing

Standstill

BOOL

The axis is in state Standstill

DiscreteMotion

BOOL

The axis is in state DiscreteMotion

ContinuousMotion

BOOL

The axis is in state ContinuousMotion