Library Reference

This is a dictionary of all referenced libraries and their name spaces.

3SLicense

Library Identification

Placeholder: 3SLicense
Default Resolution: 3SLicense, * (3S - Smart Software Solutions GmbH)
Namespace: _3S_LICENSE

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: 3SLicense

CmpApp

Library Identification

Placeholder: CmpApp
Default Resolution: CmpApp, * (System)
Namespace: CmpApp

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpApp

CmpIecTask

Library Identification

Placeholder: CmpIecTask
Default Resolution: CmpIecTask, * (System)
Namespace: CmpIecTask

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpIecTask

CmpLog

Library Identification

Placeholder: CmpLog
Default Resolution: CmpLog, * (System)
Namespace: CmpLog

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpLog

FloatingPointUtils

Library Identification

Placeholder: FloatingPointUtils
Default Resolution: FloatingPointUtils, * (System)
Namespace: FPU

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: FloatingPointUtils

SM3_AddRampsDefault

Library Identification

Placeholder: SoftMotion_AddRamps
Default Resolution: SM3_AddRampsDefault, * (3S - Smart Software Solutions GmbH)
Namespace: SoftMotion_AddRamps

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SoftMotion_AddRamps

SM3_Basic

Library Identification

Placeholder: SM3_Basic
Default Resolution: SM3_Basic, * (3S - Smart Software Solutions GmbH)
Namespace: SM3_Basic

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_Basic

SM3_CPKernelDefaults

Library Identification

Placeholder: SM3_CPKernelDefaults
Default Resolution: SM3_CPKernelDefaults, * (3S - Smart Software Solutions GmbH)
Namespace: Defaults

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_CPKernelDefaults

Library Parameter

Parameter: MAX_NUM_TRIGGERS_PER_MOVEMENT = 8

SM3_CommonPublic

Library Identification

Placeholder: SM3_CommonPublic
Default Resolution: SM3_CommonPublic, * (3S - Smart Software Solutions GmbH)
Namespace: SM3_Common

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_CommonPublic

SM3_Dynamics

Library Identification

Placeholder: SM3_Dynamics
Default Resolution: SM3_Dynamics, * (CODESYS Development GmbH)
Namespace: SMDYN

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_Dynamics

SM3_Error

Library Identification

Placeholder: SM3_Error
Default Resolution: SM3_Error, * (3S - Smart Software Solutions GmbH)
Namespace: SM3_Error

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_Error

SM3_RBase

Library Identification

Placeholder: SM3_RBase
Default Resolution: SM3_RBase, * (3S - Smart Software Solutions GmbH)
Namespace: SMRB

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_RBase

SM3_RCP

Library Identification

Placeholder: SM3_RCP
Default Resolution: SM3_RCP, * (3S - Smart Software Solutions GmbH)
Namespace: SMRCP

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_RCP

SM3_Ramps

Library Identification

Placeholder: SM3_Ramps
Default Resolution: SM3_Ramps, * (3S - Smart Software Solutions GmbH)
Namespace: SM3_Ramps

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_Ramps

SM3_Shared

Library Identification

Placeholder: SM3_Shared
Default Resolution: SM3_Shared, * (3S - Smart Software Solutions GmbH)
Namespace: SM0

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_Shared

SM3_TrajectoryGeneration

Library Identification

Placeholder: SM3_TrajectoryGeneration
Default Resolution: SM3_TrajectoryGeneration, * (3S - Smart Software Solutions GmbH)
Namespace: SM3_TrajectoryGeneration

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SM3_TrajectoryGeneration

SM3_Transformation

Library Identification

Placeholder: SM3_Transformation
Default Resolution: SM3_Transformation, * (3S - Smart Software Solutions GmbH)
Namespace: TRAFO

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SM3_Transformation

Standard

Library Identification

Placeholder: Standard
Default Resolution: Standard, * (System)
Namespace: Standard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Standard

SysMem

Library Identification

Placeholder: SysMem
Default Resolution: SysMem, * (System)
Namespace: SysMem

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysMem

SysTarget

Library Identification

Placeholder: SysTarget
Default Resolution: SysTarget, * (System)
Namespace: SysTarget

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTarget

SysTime

Library Identification

Name: SysTime
Version: 3.5.5.0
Company: System
Namespace: SysTime

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: SysTime, 3.5.5.0 (System)

SysTypes2 Interfaces

Library Identification

Name: SysTypes2 Interfaces
Version: newest
Company: System
Namespace: SysTypes

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTypes2 Interfaces, * (System)

VisuElem3DPath

Library Identification

Placeholder: System_VisuElem3DPath
Default Resolution: VisuElem3DPath, 3.5.10.0 (System)
Namespace: VisuElem3DPath

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElem3DPath

Library Parameter

Parameter: GC_POINTS_PER_POLYGON = 100

VisuElemCamDisplayer

Library Identification

Placeholder: System_VisuElemCamDisplayer
Default Resolution: VisuElemCamDisplayer, 3.5.10.0 (System)
Namespace: VisuElemCamDisplayer

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemCamDisplayer

Library Parameter

Parameter: GC_POINTS_PER_CAM = 100

VisuElemMeter

Library Identification

Placeholder: System_VisuElemMeter
Default Resolution: VisuElemMeter, 3.5.10.0 (System)
Namespace: VisuElemMeter

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemMeter

VisuElemTextEditor

Library Identification

Placeholder: System_VisuElemTextEditor
Default Resolution: VisuElemTextEditor, 3.5.10.0 (System)
Namespace: VisuElemTextEditor

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemTextEditor

VisuElemTrace

Library Identification

Placeholder: System_VisuElemTrace
Default Resolution: VisuElemTrace, 3.5.10.0 (System)
Namespace: VisuElemTrace

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemTrace

VisuElems

Library Identification

Placeholder: System_VisuElems
Default Resolution: VisuElems, 3.5.10.0 (System)
Namespace: VisuElems

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElems

VisuElemsAlarm

Library Identification

Placeholder: System_VisuElemsAlarm
Default Resolution: VisuElemsAlarm, 3.5.10.0 (System)
Namespace: VisuElemsAlarm

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsAlarm

VisuElemsDateTime

Library Identification

Placeholder: System_VisuElemsDateTime
Default Resolution: VisuElemsDateTime, 3.5.10.0 (System)
Namespace: VisuElemsDateTime

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsDateTime

VisuElemsSpecialControls

Library Identification

Placeholder: System_VisuElemsSpecialControls
Default Resolution: VisuElemsSpecialControls, 3.5.10.0 (System)
Namespace: VisuElemsSpecialControls

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsSpecialControls

VisuElemsWinControls

Library Identification

Placeholder: System_VisuElemsWinControls
Default Resolution: VisuElemsWinControls, 3.5.10.0 (System)
Namespace: VisuElemsWinControls

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsWinControls

VisuInputs

Library Identification

Placeholder: system_visuinputs
Default Resolution: VisuInputs, * (System)
Namespace: visuinputs

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: system_visuinputs

VisuNativeControl

Library Identification

Placeholder: System_VisuNativeControl
Default Resolution: VisuNativeControl, 3.5.10.0 (System)
Namespace: VisuNativeControl

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuNativeControl