SMC_GroupReadPlanningStatistics (FB)ΒΆ
FUNCTION_BLOCK SMC_GroupReadPlanningStatistics
Administrative FB for reading planning statistics.
- InOut:
- Scope - Name - Type - Comment - Inout - AxisGroup- Reference to a group of axes - Input - Enable- BOOL- Get the planning statistics of the axis group continuously while enabled - Output - Valid- BOOL- TRUEif valid outputs are available- Busy- BOOL- The FB is not finished - Error- BOOL- Signals that an error has occurred within the function block - ErrorID- SMC_ERROR- Error identification - numTimeBudgetExceeded- UDINT- The number of times the time budget for planning was exceeded. Values > 0 indicate performance problems. - numSlowDownLowIpoQueue- UDINT- The number of times the planner added samples from the stop trajectory because the Ipo queue duration is too short. - numTimeBudgetNewMovementExceeded- UDINT- The number of times the time budget for adding new movements was exceeded. Values > 0 indicate performance problems. 
