SMC_DetermineCuboidBearing (FB)ΒΆ
FUNCTION_BLOCK SMC_DetermineCuboidBearing
This function block will determine the position of a cuboid (corner mark, edge alignment) in the space in dependence of 6 (3/2/1) points given:
 
For detailed information of transformation modules see the survey on Coordinate Transformations.
- InOut:
- Scope - Name - Type - Initial - Comment - Input - A1- SMC_Vector3D- First of three points that are located on the surface A of a cube and do not lie on a common line. - A2- SMC_Vector3D- Second of three points that are located on the surface A of a cube and do not lie on a common line. - A3- SMC_Vector3D- Third of three points that are located on the surface A of a cube and do not lie on a common line. - B1- SMC_Vector3D- First of two points that are located on another cube surface B adjacent to A. The projection of this point on surface A may not coincide with the projection of B2. - B2- SMC_Vector3D- Second of two points that are located on another cube surface B adjacent to A. The projection of this point on surface A may not coincide with the projection of B1. - C1- SMC_Vector3D- Point on a further cube surface adjacent to A and B - Output - M- SMC_Vector3D- Common corner point of cube surfaces A, B and C - vAB- SMC_Vector3D- Unit vector on edge line between A and B with start point M - vBC- SMC_Vector3D- Unit vector on edge line between B and C with start point M - vCA- SMC_Vector3D- Unit vector on edge line between A and C with start point M - bError- BOOL- Signals, that an error has occurred within the function block - nError- WORD- 0 - Error description: - 0: No error ( - bError=FALSE)
- 1: A1,A2,A3 lie on common line 
- 2: Projections of B1 and B2 on surface A coincide 
 