SMC_NC_PrependDefaults (FB)¶
FUNCTION_BLOCK SMC_NC_PrependDefaults
This function block is used internally by SMC_ReadNCFile2 to prepend a sentence containing the given defaults, e.g. ‘N0 G17 F25 E1000 E-2000’. If SMC_ReadNCFile2 is used, there is not need to use this function block.
Important: this function block will prepend the defaults again after a jump command in the out queue. So it should be used before any buffering function blocks such the jump buffer. It should be called before SMC_NCNavigator as well, because the navigator will handle the jumps to unknown jump targets.
- InOut:
- Scope - Name - Type - Comment - Inout - sentencesOut- The output sentence queue - sentencesIn- The input sentence queue - Input - bExecute- BOOL- bAbort- BOOL- If - TRUE, the current processing of this function block is aborted- fDefaultVel- LREAL- Default velocity; used if the velocity (F-word) is not specified inside the CNC file. - fDefaultAccel- LREAL- Default acceleration; used if acceleration (E+ word) is not specified inside the CNC file - fDefaultDecel- LREAL- Default deceleration (E- word); used if deceleration is not specified inside the CNC file - fDefaultVelFF- LREAL- Default velocity for fast forward (G0), FF word. It is used if no velocity is specified inside the CNC file. - fDefaultAccelFF- LREAL- Default acceleration for fast forward (G0), EF+ word. It is used if no acceleration is specified inside the CNC file. - fDefaultDecelFF- LREAL- Default deceleration for fast forward (G0), EF- word. A non-negative value is expected. It is used if no deceleration is specified inside the CNC file. - b3DMode- BOOL- If - TRUE, a G17 command (activation of 3D-mode) is executed implicitly.- Output - bBusy- BOOL- bError- BOOL- ErrorID- SMC_ERROR- errorPos