SMC_SmoothMerge (FB)¶
FUNCTION_BLOCK SMC_SmoothMerge
The function block serves the preprocessing of line segments supplied by a CAD/CAM system. It is executed after decoding. It tries to approximate a maximum number of points by a polynom. The deviation from the original path must be within a given threshold. The created elements can be smoothed by use of the SMC_SmoothPath function block.
In each cycle this function block appends a maximum of one element to the out-queue.
Exactly one element is appended if the in-queue is full or bEndOfList is active and
the out-queue is not full. The look-ahead is therefore limited by the size of the
in-queue. Only movements in X, Y, Z, A, B and C are considered.
The function block uses the mean-square-best-approximation, but always pass exactly
through one first point (for avoiding jumps). This first point is given by the piDestPos
of the last generated element. If it is the first element that we deal with, this is its
piStartPos.
Only the following movement types can be merged:
All G01 movements
G00 movements without movement in X/Y/Z direction
Every other movement type or without the required feature flag will just be forwarded to the out-queue, except for one case: The first non-administrative element (i.e. no M-function, G4 etc.) after a merging block is going to be converted into a line.
Note
The function block
does only merge the additional axes A/B/C (P/Q/U/V/W are not considered)
does not support h-functions
does not support changes of flags like G51, G52, G40 and so on. These changes are ignored.
takes at most 128 line segments into account (as this quantity influences both performance and storage size).
A spline always contains the same tool correction information (i.e. lengths and diameter) as the first of the segments that it replaces.
- InOut:
Scope
Name
Type
Initial
Comment
Input
bExecuteBOOLStarts on rising edge; while
TRUE, the function block is active.poqDataInPOINTER TO SMC_OUTQUEUE
Points to the SMC_OUTQUEUE-structure object, which contains the SMC_GEOINFO objects of the unsmoothed path; typically it points to the output
poqDataOutof the preceding module (e.g. the SMC_NCDecoder).nSizeOutQueueUDINTSize of the data buffer
pbyBufferOutQueue``in bytespbyBufferOutQueuePOINTER TO ARRAY [0..0] OF SMC_GEOINFO
Points to the first byte of the memory area being allocated for the SMC_OUTQUEUE-structure. This area must be at least as big as defined in
nSizeOutQueue. Typically the allocation of the memory buffer is done within the declaration part of the IEC-program by defining an array of SMC_GeoInfo (ExampleBuf:ARRAY[1..50] OF SMC_GEOINFOfor a buffer which can hold 50 path elements). After predefining the value it may be modified during a reset only.piMaxDifferenceThe maximum allowed deviation from the original path, in X, Y, Z, A, B and C
usiMaxDegreeUSINT5
The maximal degree for the resulting polynomials, at most 5
wFeatureFlagWORDThe feature bit (0..31) used for smoothing (controlled by G38/G39)
wAdditionalParamNumberWORDThe number of the additional parameter (set by G38 I/J/K) that is used as a factor multiplied to the precision
dMinimumCurvatureRadiusLREAL0
If a possibly generated spline contains a position where its curvature radius is less than this value, it won’t be generated.
Output
bDoneBOOLWill be set to
TRUEas soon as the input data frompoqDataInhas been processed completely. Thereafter, the module will not perform any further actions until it gets reset. If thebExecuteinput isFALSE,bDonewill be reset toFALSE.bBusyBOOLTRUE, while execution of function block is not finishedbErrorBOOLSignals, that an error has occurred within the function block
wErrorIDSMC_ERRORError identification
poqDataOutPOINTER TO SMC_OUTQUEUE
The queue for the output path
uiNrElemsUINTThe number of elements that have been merged in this cycle