SMC_NCInterpreter (FB)¶
FUNCTION_BLOCK FINAL SMC_NCInterpreter
This function block is used to interpret a CNC program (Din 66025, G-code). The program is converted into a list of SMC_GeoInfo objects and stored in a queue of type SMC_OutQueue. In each call, usually one line of the program is interpreted.
This function block should be called in a separate task with a priority lower than the priority of the bus task. It should be called together with the function blocks for reading the G-Code (e.g. SMC_ReadNCFile2) and for pre-processing the path (e.g. SMC_CheckVelocities). It can be called multiple times per cycle.
Note
- The interpreter must be called in the same task as the function block that fills the SMC_GSentenceQueue (input - sentences). Usually, the sentences are provided by SMC_ReadNCFile2, SMC_ReadNCFromStream, or SMC_NCTokenParser.
- The maximum number of M-functions in a row is 64. If the G-Code contains more than 64 M-functions in a row, the error - SMC_DEC_OUTQUEUE_RAN_EMPTYoccurs. This restriction can be circumvented by inserting a G75 previous to the first M-function of the sequence. G4-elements count as M-functions, too.
- InOut:
- Scope - Name - Type - Initial - Comment - Inout - sentences- The input queue of g-code sentences - Input - bExecute- BOOL- Execution starts on the rising edge. - bAbort- BOOL- If - TRUE, the current processing of this function block is aborted- bAppend- BOOL- If - TRUE, a rising edge of- bExecutewon’t lead to a reset of the out-queue. Instead, newly incoming data will be written to the end of the out-queue.- piStartPosition- Start position of the path. Only the position of the axes (piStartPosition.dX/dY/dZ/dA/dB/dC/dA1/…/dA6) is used, the other members of piStartPosition are ignored. - vStartToolLength- SMC_Vector3d- Start tool length. - nSizeOutQueue- UDINT- This variable contains the size of the data buffer, the list of SMC_GEOINFO structure objects will be written to. This buffer must be able to hold at least five SMC_GEOINFO objects. Otherwise, the function block will not execute any actions at all. Its size may be predefined, but may be modified later only during a reset. It is recommended to create the buffer as described by the example below: - ExampleBuf: Array[1..50] of SMC_GeoInfo;- The appropriate buffer size will then be retrieved by use of the operator - sizeof(ExampleBuf).- pbyBufferOutQueue- POINTER TO ARRAY [0..0] OF SMC_GEOINFO - This input must point to the first byte of the memory area that is allocated for the SMC_OUTQUEUE structure. This area must be at least as big as defined in - nSizeOutQueue. Typically the allocation of the memory buffer is done in the declaration part of the IEC-program by defining an array of SMC_GEOINFO (e.g.- BUF: ARRAY[1..50] OF SMC_GEOINFO; for a buffer that can store 50 path elements). The value may be predefined, but may be modified later on only during a reset.- bEnableSyntaxChecks- BOOL- TRUE - Turns on syntax checks that will detect invalid G-code and stop with an error in this case. It is recommended to use the syntax checks. - eOriConv- SMC_ORI_CONVENTION.ADDAXES - Defines the way the orientation in the A/B/C words is interpreted. - For movement commands (such as G01, G02, …), the value determines how A/B/C are treated. For values other than SMC_ORI_CONVENTION.``ADDAXES``, the angles A/B/C may be normalized, even if no coordinate rotation has been programmed. For example with orientation convention ZYZ, a programmed orientation of A=90° B=0° C=0° may result in the (equivalent) rotation A=0° B=0° C=90° in the path element. - For commands that set the decoder coordinate system (G54/G55/G56), the value determines how the coordinates A/B/C are treated. If the value is SMC_ORI_CONVENTION.``ADDAXES``, then A/B/C are treated as independent additional axes, for which offsets are set. For all other values, A/B/C are treated as an orientation, and the decoder coordinate system is rotated accordingly. - Note - If used with tool correction functions such as SMC_ToolLengthCorr, the same orientation convention has to be used there. - dCircleTolerance- LREAL- Tolerance to decide whether the definition of a circle makes sense.
- case definition via target-position and radius: If the distance between start- and end-position (both projected onto the circle plane) is greater than - 2 * the radius + MAX(fCircleTolerance, 1e-06), the circle will be converted into a line.
- case definition via target- and center-position: Let - xbe the maximum of the distance between start- and center-position and the distance between target- and center-position (projecting everything onto the circle plane). If those distances differ by more than- MAX(fCircleTolerance, 0.1 * x), the circle will be converted into a line.
 
 - pInterpreterStack- POINTER TO BYTE - Allows to supply a buffer for the interpreter stack. If 0, a default buffer of size 10240 Bytes is used. If <> 0, the given buffer will be used. This input is read each cycle. - nInterpreterStackSizeBytes- UDINT- The size of the buffer pointed to by pInterpreterStack. Note that the size needs to be at least 1024 Bytes. - Output - bDone- BOOL- This variable will be set to - TRUEas soon as the input data has been processed completely. The function block will not perform any further actions until it gets reset.- bBusy- BOOL- TRUE, while execution of function block is not finished.- bError- BOOL- Signals that an error has occurred within the function block. - wErrorID- SMC_ERROR- Error identification - errorPos- The source-position where an error has been detected. - poqDataOut- POINTER TO SMC_OUTQUEUE - Pointer to the SMC_OUTQUEUE structure that manages the decoded SMC_GEOINFO objects. - iStatus- The current status. - iLineNumberDecoded- DINT- The variable contains the 0-based line number of the CNC file. - GCodeText- The G-Code text of the current line. - CallstackInfo- Information about the callstack of the current G-Code line. Used by SMC_DisplayNCCallstack. - aActivePrograms- ARRAY [0..(SoftMotion_NC2_Constants.IPR_CALLSTACK_SIZE - 1)] OF STRING - The currently active programs and subprograms. aActivePrograms[0] holds the name of the (sub)program that is currently interpreted. If it is a sub-program, then aActivePrograms[1] holds the name of the calling (sub)program and so on. The list of active programs is terminated by an empty string. 
Methods:
Structure: