SMC_TRAFOV_GantryCutter3 (FB)ΒΆ
FUNCTION_BLOCK SMC_TRAFOV_GantryCutter3
Rreverse transformation for three-dimensional gantry systems, taking into account the path velocity and path direction as control variables for the axis.
Note
For detailed information on transformations see Overview to SM_Trafo_POUs.
- InOut:
Scope
Name
Type
Initial
Comment
Input
piTarget position vector (x,y), output of interpolator
dVelLREALPath velocity, output of interpolator
vSMC_VECTOR3DTangent path vector, output of interpolator
dOffsetXLREALAdditional offset for x-axis
dOffsetYLREALAdditional offset for y-axis
dOffsetZLREALAdditional offset for z-axis
dOffsetRLREALOffset of rotation axis
iDirectionRINT1
Direction of rotation
Output
dxLREAL0
Resulting position x
dvxLREAL0
Resulting velocity x
dyLREAL0
Resulting position y
dvyLREAL0
Resulting velocity y
dzLREAL0
Resulting position z
dvzLREAL0
Resulting velocity z
drLREAL0
Rotation of resulting position in degrees