MC_MoveVelocity (FB)¶
FUNCTION_BLOCK MC_MoveVelocity
This function block causes an endless motion at a specified velocity.
- Example
- Use ofMC_MoveVelocityThe following illustration shows how two instances (FirstandSecond) of the function blockMC_MoveVelocityare combined. In the left-hand part of the illustration theSecondinstance is called after theFirstinstance. IfFirstachieves the specified velocity 3000, then theFirstoutputInVelocityis ANDed with theNextsignal. This causesSecondto move at velocity 2000.In the right-hand part of the illustration the execution is started byFirst, which aborts the previously executedSecondinstance and therefore the outputInVelocityof theSecondinstance is set to False. AlthoughFirstis still accelerating in order to reach velocity 3000, it is interrupted and aborted because theTestsignal starts the execution ofSecond. NowSecondwill decelerate the velocity to 2000 after which theInVelocityof theSecondinstance is set to TRUE.
- InOut:
- Scope - Name - Type - Initial - Comment - Inout - Axis- Reference to axis - Input - Execute- BOOL- TRUE: Starts execution.- Velocity- LREAL- Maximum velocity in techincal units per second [u/s]. - Is always positive. - Acceleration- LREAL- Acceleration in [u/s²]. - Is always positive. 
- Increasing motor energy 
 - Deceleration- LREAL- Deceleration in [u/s²]. - Is always positive. 
- Decreasing motor energy 
 - Jerk- LREAL- Maximum magnitude of jerk in [u/s³] - Direction- current - The direction of the movement. Only current, positive, and negative are allowed. - BufferMode- MC_BUFFER_MODE- Defines the chronological sequence of the FB relative to the previous block. If the function block is Busy, then only BufferMode=Aborting is allowed. - Output - InVelocity- BOOL- TRUE: The set velocity has been reached for the first time.- Busy- BOOL- TRUE: Function block is in operation.- Active- BOOL- Indicates that the FB has control on the axis - CommandAborted- BOOL- FALSE - TRUE: Execution has been interrupted by another function block instance operating on the axis.- Error- BOOL- TRUE: Error has occurred.- ErrorID- SMC_ERROR- Error identification