Settings (GVL)ΒΆ
Possible settings for the rpc stack.
- Attributes:
- qualified_only
- InOut:
- Name - Type - Initial - Comment - g_tTimeout_RequestCallback - TIME- TIME#1m0s0ms - default = T#300s; wait for the request callback of a rpc provider *) - g_uiMaxNumResends - UINT- 2 - Counter - g_uiMaxPings - UINT- 3 - Maximum Number of Pings to send without getting a response (Ping Ack) before moving to NO_CONNECTION state - g_tTimeout_Ack - TIME- TIME#1s0ms - wait before sending an ack pdu - g_tTimeout_Broadcast - TIME- TIME#5s0ms - wait for a response to a broadcast pdu - g_tTimeout_Cancel - TIME- TIME#10s0ms - wait for a response to a cancel pdu - g_tTimeout_Frag - TIME- TIME#2s0ms - wait for a fack pdu if the no_fack flag was cleared (Burst disabled) - g_tTimeout_Idle - TIME- TIME#1m0s0ms - default = T#300s; time for keeping the state information about the client *) - g_tTimeout_Ping - TIME- TIME#2s0ms - wait for a response to a ping pdu - g_tTimeout_ResendPing - TIME- TIME#3s0ms - wait for a response to a ping pdu after resending a request - g_tTimeout_Resend - TIME- TIME#5s0ms - wait for acknowledgement from client before retransmitting a response - g_tTimeout_Wait - TIME- TIME#60m0s0ms - wait for a response to a request pdu