SF_Antivalent (FB)ΒΆ
FUNCTION_BLOCK SF_Antivalent
- InOut:
Scope
Name
Type
Initial
Comment
Input
ActivateBOOLFALSE
Activation of the FB.
S_ChannelNCBOOLFALSE
Input for NC (Normally Closed) connection. FALSE: NC contact open, TRUE: NC contact closed.
S_ChannelNOBOOLFALSE
Input for NO (Normally Open) connection. FALSE: NO contact open, TRUE: NO contact closed.
DiscrepancyTimeTIMETIME#0ms
Maximum monitoring time for discrepancy status of both inputs
Output
ReadyBOOLFALSE
Activation of the FB. TRUE indicates that the FB is activated and the outputs results are valid, FALSE the FB is not active and the program is not executed.
S_AntivalentOutBOOLFALSE
Safety related output
SafetyDemandBOOLFALSE
Output indicating that the FB is active and the primary safety function is demanded (e.g. related to the safety functionality).
ErrorBOOLFALSE
Error flag
DiagCodeWORD0
Diagnostic register