MQTTConnectProperties (STRUCT)ΒΆ
TYPE MQTTConnectProperties : STRUCT
Connect properties (MQTT V5)
- InOut:
- Name - Type - Comment - udiSessionExpiryInterval- UDINT- Session Expiry Interval: Time in seconds a session retains after a disconnect. - wsAuthenticationMethod- WSTRING- Name of the authentication method - pbAuthenticationData- POINTER TO BYTE - Binary Data containing authentication data - udiAuthenticationDataSize- UDINT- Size of pbAuthenticationData - bRequestProblemInformation- BYTE- The Client uses this value to indicate whether the Reason String or User Properties are sent in the case of failures. - bRequestResponseInformation- BYTE- This value can be used to request the Server to return Response Information. - uiReceiveMaximum- UINT- The Client uses this value to limit the number of QoS 1 and QoS 2 publications that it is willing to process concurrently. There is no mechanism to limit the QoS 0 publications that the Server might try to send. - uiTopicAliasMaximum- UINT- This value indicates the highest value that the Server will accept as a Topic Alias sent by the Client. - udiMaximumPacketSize- UDINT- The Client uses the Maximum Packet Size to inform the Server that it will not process packets exceeding this limit. - userProperties- ARRAY [0..(MQTTParam.g_udiMaxUserProperties - 1)] OF MQTTStringPair - User defined properties