MQTTPublish (FB)¶
FUNCTION_BLOCK MQTTPublish EXTENDS CBML.ETrigTo IMPLEMENTS IClientAction
Function block to publish (send) messages to a MQTT broker Use the input udiTimeout (see CBML.ETrigTo) to set the time in µs in which an acknowledgement must be received (relevant for QoS1 and QoS2). Default: 1s
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xExecute- BOOLRising edge: Starts defined operation- FALSE: Resets the defined operation after ready condition was reached- ETrigTo - udiTimeOut- UDINT- Max. operating time for executing [µs], 0: No operating time limit - ETrigTo - Output - xDone- BOOL- Ready condition reached - ETrigTo - xBusy- BOOL- Operation is running - ETrigTo - xError- BOOL- Error condition reached - ETrigTo - Input - eQoS- QoS Level of message - xReDelivery- BOOL- TRUE: When packet got already send and now should got resend, FALSE: First time - xRetain- BOOL- TRUE: Stores the message on server - pbPayload- POINTER TO BYTE - Pointer to the message - udiPayloadSize- UDINT- Size of message - mQTTPublishProperties- REFERENCE TO MQTTPublishProperties - Optional publish properties (MQTT V5 only) - Inout - mqttClient- Function block MQTTClient - wsTopicName- WSTRING(1024)- Topic Name of message - Output - eMQTTError- MQTT Error type