Generic_Service (FB)ΒΆ
FUNCTION_BLOCK Generic_Service EXTENDS BaseService
This function block performs a generic service at an EtherNet/IP Adapter. The message will be sent as an unconnected explicit message request.
Note
Data received and send needs to be swapped. See parent folder.
/// Force trigger to TRUE to activate.
/// Example device used here is WAGO 750-352 FC ETHERNET.
/// But you can adapt it, by using the services which are implemented by your prefered device.
PROGRAM PLC_PRG
VAR
    dut : ENIP.Generic_Service ;
    data: usint:=16#FF;
    trigger: BOOL;
END_VAR
    dut.xExecute := trigger;
    dut.itfEtherNetIPDevice := WAGO_750_352_FC_ETHERNET;
    dut.eClass := 100;
    dut.dwInstance := 1;
    dut.wAttribute := 11;
    dut.eService := ENIP.CIPCommonService.SET_ATTRIBUTE_SINGLE;
    dut.pWriteData := ADR(data);
    dut.udiWriteDataSize := 1;
    dut();
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrig - Output - xDone- BOOL- TRUE: Action successfully completed- ETrig - xBusy- BOOL- TRUE: Function block active- ETrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrig - Input - itfEtherNetIPDevice- IEtherNetIPService- BaseService - eClass- BaseService - dwInstance- DWORD- BaseService - Output - eError- BaseService - Input - wAttribute- WORD- Attribute the services is addressed to. Leave 0 if this service does not address an attribute. - eService- Choose one of the CIPCommonService members, or insert any vendor specific service code. - pWriteData- POINTER TO BYTE - Data to write to the EtherNet/IP Adapter. Leave 0 if no data should be sent to the EtherNet/IP Adapter. - udiWriteDataSize- UDINT- Size of data to write to the EtherNet/IP Adapter. Leave 0 if no data should be sent to the EtherNet/IP Adapter. - pReadData- POINTER TO BYTE - Data expected to receive from the EtherNet/IP Adapter. Leave 0 if no data is expected to be received from the EtherNet/IP Adapter. - udiReadDataSize- UDINT- Size of data expected to receive from the EtherNet/IP Adapter. Leave 0 if no data is expected to be received from the EtherNet/IP Adapter. - Output - udiReceivedDataSize- UDINT- Size of the received data 