ReadWriteEEprom (FB)ΒΆ
FUNCTION_BLOCK ReadWriteEEprom
Read or write the EEprom of an EtherCAT slave device
- InOut:
- Scope - Name - Type - Initial - Comment - Input - xExecute- BOOL- Rising edge: ACTION starts Falling edge: Resets outputs If a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone, xError) are present at the outputs for exactly one cycle. - usiCom- USINT- Instance of master - uiSlaveAddress- UINT- Address of slave 1001 + n or Autoincrement address if bAutoIncrementAddress is set - pbyData- POINTER TO BYTE - Pointer to 2048 bytes - udiByteSize- UDINT- 2048 - Number of Bytes to write or read - xWrite- BOOL- FALSE - True: EEprom should be written - uiStartEEpromAddress- UINT- 16#0 - Start of Eeprom address to read or write - bAutoIncrementAddress- BOOL- FALSE - True: access should be done with auto increment address, False: Access with physical address - bWaitForPackets- BOOL- TRUE - True: The function block should wait for the packets. - Output - xDone- BOOL- TRUE: Action successfully completed - xBusy- BOOL- TRUE: Function block active - xError- BOOL- TRUE: Error occurred, function block aborts action, FALSE: No error 