ETC_FoE_Download (FB)ΒΆ
FUNCTION_BLOCK ETC_FoE_Download
Function block to download a file from the EtherCAT Slave. Could be also used for downloading a firmware file to the slave. Slave must be set to boot mode with pSlave^.SetOpMode(3); first in this case.
- InOut:
- Scope - Name - Type - Initial - Comment - Input - xExecute- BOOL- Rising edge: ACTION starts Falling edge: Resets outputs If a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone, xError) are present at the outputs for exactly one cycle. - usiCom- USINT- 1 - Index of master 1: first ETC master - uiDevice- UINT- The physical slave address to access the EtherCAT slave - usiChannel- USINT- 1 - not used in the moment because channel is set automatically - pbyData- POINTER TO BYTE - Pointer to the data of the file - udiDataSize- UDINT- Size of data - dwPassword- DWORD- Password for file transfer - strFilename- STRING- Filenname to save on the EtherCAT slave - Output - xDone- BOOL- TRUE: Action successfully completed - xBusy- BOOL- TRUE: Function block active - xError- BOOL- TRUE: Error occurred, function block aborts action, FALSE: No error - Errorcode- if xError is true, then this output shows the error reason - strErrorText- STRING- Error code as an string