LConTlTo (FB)

FUNCTION_BLOCK LConTlTo EXTENDS LConTl IMPLEMENTS ILConTlTo

Base implementation of a PLCopen Level Controlled Behavior Model (see: ILConTlTo) For use, this block should be extended and the specific inputs and outputs must be supplemented. The output eErrorID of the application-specific enum type ERROR must be added.

InOut:

Scope

Name

Type

Comment

Inherited from

Input

xEnable

BOOL

TRUE: Activates the defined operation FALSE: Aborts/resets the defined operation

LConTl

udiTimeLimit

UDINT

Max. operating time per invocation [µs], 0: No operating time limit

LConTl

Output

xDone

BOOL

TRUE: Ready condition reached

LConTl

xBusy

BOOL

TRUE: Operation is running

LConTl

xError

BOOL

TRUE: Error condition reached

LConTl

Input

udiTimeOut

UDINT

Max. operating time for executing [µs], 0: No operating time limit

Properties:

Methods:

Structure: